Setting the time zone

Don’t use words in standard dictionaries, even if you use them backward or in a foreign language. Create your own acronyms instead.

Don’t use proper names, especially company names or those of famous people.

Use a combination of uppercase and lowercase characters, numerals, and special characters (such as Im4e@tiN9).

Setting the time zone

The Firebox time zone determines the date and time stamp that appear on logs and that are displayed by services such as LogViewer, Historical Reports, and WebBlocker. Use the time zone to view log information in local time. The default time zone is Greenwich Mean Time (Coordinated Universal Time).

From Policy Manager in the Advanced view:

1Select Setup =>Time Zone.

2Use the drop list to select a time zone. Click OK.

Check the drop list carefully. WatchGuard provides a comprehensive list of time zones to accommodate areas in the same general time zone that follow different rules regarding the observance and/or onset and rollback of Daylight Saving Time, and other timekeeping details.

Reinitializing a misconfigured Firebox

The Firebox can boot from the primary area of the flash disk (Sys A) in a mode that provides fail-safe access in cases when you need to:

Install a Firebox for the first time

Troubleshoot problems in which all access to the Firebox is lost

Reset Firebox passwords when you do not know or have forgotten them

This Enhanced System Mode is the default mode for new Fireboxes shipped from the factory. If a Firebox is in this mode, its Sys A light blinks. A Firebox can also be placed into Enhanced System Mode by connecting any two of the Firebox Ethernet interfaces in a loopback configuration. Use a red crossover cable included with the Firebox for this purpose.

To access a Firebox in Enhanced System Mode:

1Establish a physical Ethernet connection between the Trusted interface of the Firebox and the Management Station on the same segment.

2Attach the red crossover cable between the remaining two Firebox interfaces, and then turn the power on the Firebox off and then on. If a small, “factory default” switch is present on the rear of the Firebox, press and hold that switch while you

turn the Firebox power off and then on.

The Firebox boots into the Enhanced System Mode. This is indicated by a blinking Sys A light.

3Reinitialize the Firebox using the QuickSetup wizard.

For more information on the QuickSetup wizard, see the Install Guide.

VPN Manager Guide

25

Page 35
Image 35
WatchGuard Technologies FireboxTM System 4.6 manual Setting the time zone, Reinitializing a misconfigured Firebox