Checking Front
Panel Display Error
Messages
Troubleshooting Information
Checking the E5810
This table shows E5810 front panel display error messages and typical cause(s) for the error message.
Error Message |
| Description |
|
| |
Firmware Update | The firmware update failed. Verify that the IP address of the ftp server, | |
not successful | login, user password and filename are correct. | |
|
| |
ERROR: NV RAM | Configuration nonvolatile data memory was corrupt. All data were | |
Setting defaults | restored to factory defaults, per the nonvolatile RAM (Random Access | |
| Memory). | |
|
| |
ERROR: Selftest | A | |
See syslog | message by typing http://<IP Address>/systemLog.htm. | |
|
| |
ERROR: No LAN | LAN Link integrity not detected. Make sure the LAN cable is connected | |
connection found | and the LAN is active. | |
|
| |
ERROR: IP in use | The E5810 tried to use an IP address that is currently being used by | |
<addr> | another device on the network. Try these actions: | |
|
| Reboot the E5810 with the Preset button depressed to set the |
|
| E5810 back to booting with DHCP enabled. |
|
| OR |
|
| Remove other device(s) from the network and reboot the E5810 |
|
| OR |
|
| Move the E5810 to a Local network, disable DHCP, and set the |
| E5810 to an unused IP Address. | |
|
|
|
Chapter 4 | 115 |