Appendix B 1 45
Using the Telnet Utility
Telnet Commands for the E5810
Command Description
gpib-name <string*15> View/Set the GPIB SICL Interface Name
gpib-address <0-30> View/Set the GPIB System Controller Address
gpib-unit <1-255> View/Set the GPIB Logical Unit Number
rs232-name <string*15> View/Set the RS-232 SICL Interface Name
rs232-baud
<300|1200|2400|4800|9600|
19200|38400|57600|115200>
View/Set Baud Rate
rs232-bits <5|6|7|8> View/Set number of RS-232 data Bits
rs232-stopbits <1|2> View/Set number of RS-232 Stop Bits
rs232-parity
<NONE|EVEN|ODD|MARK|
SPACE>
View/Set the RS-232 Parity
rs232-flow
<NONE|XON|RTS|DTR> View/Set the RS-232 Flow Control
rs232-srq <RI|DSR|DCD|CTS> View/Set the RS-232 SRQ Line
status View the LAN/GPIB Gateway Connection Status
syslog-display View Contents of the Syslog
syslog-clear Clear the Syslog
password Enter the Password (when prompted)
(Password is required when making changes)
changepassword Change the Password (when prompted)
reboot Save Configuration and Reboot E5810
factory-reset Reset Config to Factory Defaults and Reboot
exit E xit WITHOU T Saving Configuration (see reboot )
quit E xit WITHOU T Saving Configuration (see reboot )
bye Exit WITHOUT Saving Configuration (see reboot)