example, when one or more logical drives have been deleted, the array indexing is changed after system reboot. The second logical drive might become the first on the list.

Choose the logical drive you wish to assign a name, then press [ENTER]. Choose “logical drive name,” then press [ENTER] again. The current name will be displayed. You may now enter a new name in this field. Enter a name, then press [ENTER] to save the configuration.

Rebuilding a Logical Drive

If there is no spare drive in the system, a failed drive should be immediately replaced by a drive known to be good. Once the failed drive is replaced, the rebuild process can be manually initiated.

If you want the controller to auto-detect a replacement drive, make sure you have the following items set to enabled:

1.Periodic Drive Check Time

2.Periodic Auto-Detect Failure Drive Swap Check Time

These two configuration options can be found under “View and Edit Configuration Parameters” ->Drive-Side SCSI Parameters”.

Choose the logical drive that has a failed member drive, then press [ENTER]. Choose “Rebuild logical drive”, then press [ENTER]. When prompted to “Rebuild Logical Drive?,” select Yes.

The rebuild progress will be displayed.