NOTE:

The rebuild priority determines how much of controller resources is conducted when rebuilding a logical drive. The default setting of the rebuild priority is “LOW.” Rebuild will have smaller impact on host I/O access, but rebuild will take a longer time to complete. Changing the rebuild priority to a higher level you will have a faster rebuild, but will certainly increase the Host I/O response time. The default setting “LOW” is recommended.

5.9Viewing and Editing Logical Drives and Drive Members

Press ENT for two seconds to enter the Main Menu. Press or to select "View and Edit Logical Drives..,” then press ENT.

Press or to select the logical drive, then press ENT.

Press or to select “View SCSI Drives..", then press ENT .

Press or to scroll through the list of member drives.

Deleting a Logical Drive

Press ENT for two seconds to enter the Main Menu. Press or to select "View and Edit Logical Drives," then press ENT.

Press or to select a logical drive, then press ENT.

Press or to select “Delete Logical Drive," then press ENT .

Press ENT for two seconds to delete. The selected logical drive has now been deleted.

View and Edit Logical Drives

LG0 RAID5 DRV=3 2012MB GD SB=1

View SCSI Drives

..

C=1 I=0 1010MB

LG=0 LN SEAGATE

View and Edit Logical Drives

LG0 RAID5 DRV=3 2012MB GD SB=1

Delete Logical

Drive ..

LG=0

 

Not Defined

?

Front Panel Operation

5-16

Page 84
Image 84