3.2.3NPC Onboard

3.2.3NPC Onboard

NPC is short for Notification Processing Center, a sub-module for use with system event notification.

To activate the NPC module, do the following:

1.Create an NPC configuration file (in a simple text file format) using a text editor program.

2.Save it in the name of “agent.ini”

3.FTP it to the controller IP address, and then reset the controller for the configuration to take effect.

Listed below is the sample configuration. Specify your configuration using simple defining parameters as shown below.

[SNMP_TRAP]

ENABLED=0 (1=on; 0=off) SEVERITY=1 COMMUNITY=public RECEIVER1=XXX.XXX.XXX.XXX,2 ("2" specifies the level of

events to be received by this receiver)

[EMAIL]

ENABLED=0

SEVERITY=1 SUBJECT=Event Message

SENDER_MAIL_BOX=XXXX@XXXXX.XXX SMTP_SERVER=XXX.XXX.XXX.XXX RECEIVER1=XXXX@XXXXX.XXX,3 RECEIVER2=XXXX@XXXXX.XXX,1 RECEIVER3=XXXX@XXXXX.XXX,2 RECEIVER4=XXXX@XXXXX.XXX,1

[BROADCAST]

ENABLED=0

SEVERITY=1 RECEIVER=XXX.XXX.XXX.XXX, 1 RECEIVER=XXX.XXX.XXX.XXX, 1

NOTE:

NPC will be automatically activated if any of the notifier settings (email, SNMP, or broadcast) is set to “enabled.”

The configuration file is comprised of three major sections: SNMP, Email and Broadcast. Each notifying method can be separately enabled or disabled.