WARNING!

Pass-through SCSI Commands are only intended to perform maintenance functions for a drive or device on the drive side. Do not perform any destructive commands to a disk drive (i.e., any commands that write data to a drive media). If a disk drive is a spare drive or a member of a logical drive, such a destructive command may cause a data inconsistency.

When a drive/device is mapped to a host SCSI ID so that Pass-through SCSI Commands can be used, the data on that drive/device will not be protected by the controller. Users who employ Pass-through SCSI Commands to perform any write commands to drive media do so at their own risk.

5.11Viewing and Editing SCSI Drives

Scanning New SCSI Drive

Press ENT for two seconds to enter the Main Menu. Press or to select "View and Edit SCSI Drives," then press ENT.

SCSI drive information will be displayed on the LCD. Press ENT on a drive. Use or to select “Scan New SCSI Drive," then press ENT again.

Press or to select a SCSI channel, then press ENT for two seconds.

Press or to select a SCSI ID, then press ENT for two seconds.

The information of the scanned SCSI drive will be displayed on the LCD.

If the drive was not detected on the selected SCSI channel and ID, the LCD will display “Scan Fail!”

View and Edit SCSI Drives

Scan new SCSI

Drive ..

Scan Channel=1 ?

Scan Channel=1

 

ID= 01

?

C=1 I=0 1010MB

NEW DRV SEAGATE

Scan Channel=1 ID=1 Scan Fail!