Maximum Queued I/O Count:

This function allows you to configure the maximum number of I/O queue the controller can accept from the host computer.

Choose “Host-side SCSI Parameters,” then press [ENTER]. Choose “Maximum Queued I/O Count,” then press [ENTER]. A list of available selections will appear. Move cursor bar to an item, then press [ENTER]. Choose Yes in the dialog box that follows to confirm the setting.

The controller supports the following Host-side SCSI configurations: “Maximum Queued I/O Count,” “LUNs per Host SCSI ID,” “Num of Host-LUN Connect,” “Tag per Host-LUN Connect,” “Peripheral Dev Type Parameters,” and “Cyl/Head/Sector Mapping Config.”

LUNs per Host SCSI ID

 

Choose “LUNs per Host SCSI ID,” then press [ENTER]. A list of

 

selections will appear. Move cursor bar to an item, then press

 

[ENTER]. Choose Yes in the dialog box that follows to confirm the

 

setting.

 

 

 

LUN Applicability:

 

If no logical drive has been created and mapped to a host LUN, and

 

the RAID controller is the only device connecting to the host SCSI

 

card, usually the operating system will not load the driver for the

 

 

9-13

Infortrend

Page 198
Image 198
Compaq Infortrend manual Maximum Queued I/O Count, LUNs per Host Scsi ID, LUN Applicability