Compaq Infortrend Optimization Mode and Stripe Size, Optimization for Random or Sequential I/O

Models: Infortrend

1 347
Download 347 pages 43.22 Kb
Page 122
Image 122
Manual background

Optimization Mode and Stripe Size

Each controller optimization mode has preset values for the stripe size of arrays created in different RAID levels. If you want a different value for your array, you may change the controller optimization mode, reset the controller, and then go back to create the array. Once the array is created, stripe size can not be changed.

Using the default value should be sufficient for most applications.

 

Opt. for Sequential I/O

Opt. for Random I/O

RAID0

128

32

RAID1

128

32

RAID3

16

4

RAID5

128

32

Optimization for Random or Sequential I/O

Choose “Optimization for Random I/O” or “Optimization for Sequential I/O,” then press [ENTER]. The “Random” or “Sequential” dialog box will appear, depending on the option you have selected. Choose Yes in the dialog box that follows to confirm the setting.

Write-Back/Write-Through Cache Enable/Disable

Choose “Caching Parameters”, then press [ENTER]. Select “Write- Back Cache,” then press [ENTER]. “Enabled” or “Disabled” will

Terminal Operation

7-3

Page 122
Image 122
Compaq Infortrend manual Optimization Mode and Stripe Size, Optimization for Random or Sequential I/O, Terminal Operation