Compaq Infortrend manual Adding a Global Spare Drive, Rebuild Settings, 5-15

Models: Infortrend

1 347
Download 347 pages 43.22 Kb
Page 83
Image 83
Adding a Global Spare Drive

Adding a Global Spare Drive

Press ENT for two seconds to enter the Main Menu. Press or to select "View and Edit SCSI Drives," then press ENT.

SCSI drive information will be displayed on the LCD. Press or to select a SCSI drive that has not been assigned to any logical drive yet, then press ENT.

Press or to select “Add Global Spare Drive,” then press ENT.

Press ENT again for two seconds to add the spare drive. The message “Add Global Spare Drive Successful” will be displayed on the LCD.

View and Edit SCSI Drives

C=2 I=4 1010MB

NEW DRV SEAGATE

Add Global Spare

Drive ..

Add Global Spare Drive Successful

Rebuild Settings

Press ENT for two seconds to enter the Main Menu. Press or to select "View and Edit Config Parms," then press ENT.

Press or to select “Disk Array Parameters,” then press ENT.

Press or to select “Rebuild Priority Low,” then press ENT. “Low” refers to the temporary setting.

Press ENT again and the abbreviation mark “..” will change to question mark “?”. Press or to select priority “Low,” “Normal,” “Improved,” or “High”.

Press ENT to confirm and the question mark “?” will turn into “..”.

View and Edit Config Parms

Disk Array

Parameters..

Rebuild Priority

Low ..

Rebuild Priority

Low?

Rebuild Priority

High..

5-15