Compaq Infortrend manual Assigning Spare Drive and Rebuild Settings, Adding a Local Spare Drive

Models: Infortrend

1 347
Download 347 pages 43.22 Kb
Page 82
Image 82
5.8Assigning Spare Drive and Rebuild Settings

you can map the whole capacity to a host LUN.

Mapping information will be displayed on the subsequent screen. Press ENT for two seconds to confirm the LUN mapping.

CH=0 ID0 LUN0

MAP to LV=0 PRT=0?

With any of the Host ID/LUN successfully associated with a logical capacity, the “No Host LUN” message in the main menu will change to “Ready.”

If you want to create more host IDs, please move to section 5.11 for more details on channel mode and channel IDs setting.

5.8Assigning Spare Drive and Rebuild Settings

Adding a Local Spare Drive

Press ENT for two seconds to enter the Main Menu. Press or to select "View and Edit SCSI Drives," then press ENT.

SCSI drive information will be displayed on the LCD. Press or to select a drive that is stated as “NEW DRV” or “USED DRV” that has not been assigned to any logical drive, as spare drive or failed drive, then press ENT to select it.

Press or to select “Add Local Spare Drive,” then press ENT.

Press or to select the logical drive where the Local Spare Drive will be assigned, then press ENT for two seconds to confirm.

The message “Add Local Spare Drive Successful” will be displayed on the LCD.

View and Edit SCSI Drives

C=2 I=4 1010MB

NEW DRV SEAGATE

Add Local Spare

Drive ..

LG0 RAID5 DRV=3 2012MB GD SB=0

Add Local Spare Drive Successful

5-14

Infortrend

Page 82
Image 82
Compaq Infortrend manual Assigning Spare Drive and Rebuild Settings, Adding a Local Spare Drive