Compaq Infortrend manual Advanced Features

Models: Infortrend

1 347
Download 347 pages 43.22 Kb
Page 285
Image 285

Auto-scan of replacement

Supported

drive upon manually

 

initiated rebuild

 

One-step rebuild onto a

Supported

replacement drive

 

Immediate logical drive

Supported

availability

 

Auto-rebuild onto failed

Supported. With no spare drive, the controller will

drive replacement

auto-scan the failed drive and starts rebuild

 

automatically once the failed drive has been replaced.

Background firmware

Firmware can be downloaded during active I/Os.

download

Administrators may find appropriate time to reset

 

controller later.

Auto recovery from logical

Supported. When user accidentally removed the

drive failure

wrong drive to cause the 2nd drive failure of a one-

 

drive-failed RAID5 / RAID3 logical drive, fatal error may

 

occur. However, you may force the controller to

 

reaccept the logical drive by switching off the controller,

 

installing the drive back to its original drive slot, and

 

then power on the controller. The logical drive will be

 

restored to the one-drive-failed status.

Advanced Features:

Media Scan

Supported. Verify written data on drives to avoid bad

 

blocks from causing data inconsistency.

Transparent reset of hung

Supported

HDDs

 

Auto cache flush on critical

When critical conditions occur, e.g., component failure,

conditions

or BBU under charge, cached data will be flushed and

 

the write policy will be changed to write-through mode.

Drive Low-level format

Supported

Drive Identification

Supported. Force the drive to light on the activity

 

indicator for user to recognize the correct drive.

 

 

Drive Information Listing

Supported. Drive vendor name, model number,

 

firmware revision, capacity (blocks), serial number,

 

narrow/wide and current sync. speed.

Drive Read/Write testing

Supported

Configuration on Disk

Supported. The logical drive information is recorded

 

on drive media. The logical drives can still be

 

accessed if using different Infortrend RAID

 

controllers/subsystems.

Save/ Restore NVRAM to /

Supported. Save all the settings stored in the

from Disks

controller NVRAM to the logical drive members

Save / Restore NVRAM to /

Supported. Save all the settings stored in the

from a file

controller NVRAM to a file (via GUI manager) on user’s

 

computer.

B-2