Compaq Infortrend manual Idle Drive Failure Detection

Models: Infortrend

1 347
Download 347 pages 43.22 Kb
Page 208
Image 208
Idle Drive Failure Detection

long as no host accesses that drive. Changing the check time to any other value allows the controller to check – at the selected time interval – all of the drives that are listed under “View and Edit SCSI Drives.” If any drive is then removed, the controller will be able to know – even if no host accesses that drive.

Idle Drive Failure Detection

Periodic Auto-Detect Failure Drive Swap Check Time

The “Drive-Swap Check Time” is the interval at which the controller checks to see whether a failed drive has been swapped. When a logical drive’s member drive fails, the controller will detect the failed drive (at the selected time interval). Once the failed drive has been swapped with a drive that has adequate capacity to rebuild the logical drive, the rebuild will begin automatically.

The default setting is “Disabled,” meaning that the controller will not Auto-Detect the swap of a failed drive. To enable this feature, select a time interval.

Choose “Periodic Drive Check Time;” then press [ENTER]. Move cursor to the desired interval; then press [ENTER]. Choose Yes in the dialog box that follows to confirm the setting.

9-23

Infortrend

Page 208
Image 208
Compaq Infortrend manual Idle Drive Failure Detection