4.3 Logical Drive Status

4.3 Logical Drive Status

Logical Drive RAID level Number of drives

LG0 RAID5 DRV=3 LG=0 RAID5 DRV=3

2021MB GD SB=1 2021MB GD SB=1

Logical Drive status

Logical Drive:

The Logical Drive number.

RAID level:

The RAID level used in this logical drive

Drive numbers:

The number of physical drives included in

 

this configuration.

Logical Drive status:

 

XxxxMB

The capacity of this logical drive.

SB=x

Standby drives available to this logical

 

drive. Except the spares dedicated to other

 

logical configurations, all spare drive(s) will

 

be counted in this field, including Global

 

and Local Spares.

xxxxMB INITING

The logical drive is now initializing.

xxxxMB INVALID

For firmware version before 3.31:

 

The logical drive has been created with

 

“Optimization for Sequential I/O”, but the

 

current setting is “Optimization for

 

Random I/O.”

 

-OR-

 

The logical drive has been created with

 

“Optimization for Random I/O,” but the

 

current setting is “Optimization for

 

Sequential I/O.”

 

Firmware version 3.31 has separate settings

 

for array optimization and array stripe size.

 

This message will not appear when the

 

optimization mode is changed.

xxxxMB GD SB=x

The logical drive is in good condition.

xxxxMB FL SB=x

One drive failed in this logical drive.

xxxxMB RB SB=x

Logical Drive is rebuilding.

xxxxMB DRVMISS

One of the drives is missing.

INCOMPLETE

Two or more drives failed in this logical

ARRAY

drive.

4-2

Infortrend

Page 63
Image 63
Compaq Infortrend manual Logical Drive Status, LG0 RAID5 DRV=3 LG=0 RAID5 DRV=3 2021MB GD SB=1 2021MB GD SB=1, RAID level