I2C Device:

2-Line LCD Temp Sensor_ Failure Detected

Terminal [3F23] Peripheral Device ALERT: Temperature Sensor_ Failure Detected

Event Type

!Alert

"Warning

"Notification

What The designated temperature sensor has failed. This may be caused by Happens? mistakes with device target setting or device failure.

What to

Check I2C cable connection and contact your system supplier.

Do?

 

 

 

 

 

 

 

2-Line LCD

Temp Sensor_ Not Present

 

 

Terminal

[3F23] Peripheral Device ALERT: Temperature Sensor_ Not Present

Event Type

!Alert

"Warning

"Notification

What The controller failed to detect the presence of the designated Happens? temperature sensor.

What to

Check I2C cable connection, I2C device setting, and contact your

Do?

system supplier.

 

 

 

 

 

2-Line LCD

High/Low (_) Temperature_ Detected

 

Terminal

[3F23] Peripheral Device ALERT: <high/low threshold> Temperature_

 

Detected (_(F/C))

 

 

Event Type

!Alert

"Warning

"Notification

What

Critical high or low temperature detected.

 

Happens?

 

 

 

What to

Check enclosure ventilation status, and then contact your system

Do?

provider for help. .

 

 

 

 

 

 

2-Line LCD

Fan_ Failure Detected

 

 

Terminal

[3F22] Peripheral Device ALERT: FAN_ Failure Detected

Event Type

!Alert

"Warning

"Notification

What

Cooling fan failure detected by I2C enclosure management.

Happens?

 

 

 

What to

Check cooling fan(s) status, and contact your system supplier.

Do?

 

 

 

 

 

 

 

2-Line LCD

Fan_ Not Present

 

 

Terminal

[3F22] Peripheral Device ALERT: FAN_ Not Present

Event Type

!Alert

"Warning

"Notification

What

The controller failed to detect the presence of the designated

Happens?

temperature sensor.

 

 

What to

Check I2C cable connection, I2C device setting, and contact your

Do?

system supplier.

 

 

2-Line LCD Fan (_._) Speed Detected (_RPM)

Event Messages

D-25

Page 325
Image 325
Compaq Infortrend manual Check I 2C cable connection and contact your system supplier