Compaq Infortrend manual Redundant Configuration Using Manual Setting, Enable Redundant Controller

Models: Infortrend

1 347
Download 347 pages 43.22 Kb
Page 234
Image 234
Redundant Configuration Using Manual Setting

Power-off controller 1, and then power on controller 2. Set controller 2 to "Autocfg" as described previously. Power off controller 2.

When the redundant controller function is set to the "Autocfg" setting, the controllers will decide between themselves which will be the Primary controller. If you need to specify a particular controller as Primary or Secondary, do not set it as "autocfg;" choose "Primary" or "Secondary" instead. Please refer to the following section for more detail.

Redundant Configuration Using Manual Setting

Power on controller 1. Make sure controller 2 is powered-off.

1. Enable Redundant Controller

Press [ENT] for two seconds on the front panel of controller 1 to enter the main menu. Use or to navigate through the menus. Choose "View and Edit Peripheral Dev..," then press [ENT].

View and Edit Peripheral Dev

Choose "Set Peripheral Device Entry," then press [ENT].

Choose "Redundant Ctlr Function__," and then press [ENT]. (Note: The current setting will be displayed on the LCD. If this controller has never been set as a redundant controller before, the default setting of the redundant controller function is "disabled." The message "Redundant Ctlr Function Disable" will be displayed on the LCD screen. Press [ENT] to proceed.)

The message "Enable Redundant Ctlr: Autocfg?" will appear. Use or to scroll through the available options ("Primary," "Secondary," or "Autocfg"). Press [ENT] for two seconds on "Primary."

2. Controller Unique ID

Enter “View and Edit Config Parms”-> “Controller Parameters”. Use or to find “Ctlr Unique ID- xxxxx”.

This value will be used to generate a controller- unique WWN node name and port names and to identify the controller during the failover process.

Set Peripheral Devices Entry

Redundant Ctlr Function Disable

Enable Redundant Ctlr: Autocfg ?

View and Edit Config Parms

Controller Parameters ..

Ctlr Unique

 

ID- 00012

?

Redundant Controller

10-21

Page 234
Image 234