When rebuilding is already started or the logical drive is being rebuilt by a Local Spare Drive or Global Spare Drive, choose “Rebuild Progress” to see the rebuild progress.

LG0 RAID5 DRV=3 2012MB RB SB=0

Rebuild Progress

..

IMPORTANT!

The Rebuild function will appear only if a logical drive (with RAID level 1, 3 or 5) has a failed member.

Use the "Identify Drive" function to check the exact location of a failed drive. Removing the wrong drive may cause a logical drive to fail and data loss is unrecoverable.

Regenerating Logical Drive Parity

If no verifying method is applied to data writes, this function can be manually performed to ensure that parity errors can be mended.

From the Main Menu, press or to select "View and Edit Logical Drives."

If you have more than one logical drive, use the or to select the logical drive you would like to check the parity for; and then press ENT.

Press or to select "Regenerate Parity" and then press ENT.

To stop the regeneration process, press ESC and enter the submenu to select “Abort Regenerate Parity”.

View and Edit Logical Drives

LG0 RAID5 DRV=3 4095MB GD SB=0

Regenerate

Parity ..

Abort Regenerate

Parity ..

IMPORTANT!

If Parity Regenerating process is stopped by a drive failure, the process cannot restart until the logical drive is rebuilt.

5-19

Infortrend

Page 87
Image 87
Compaq Infortrend manual Regenerating Logical Drive Parity, LG0 RAID5 DRV=3 2012MB RB SB=0 Rebuild Progress