1.5Identifying Drives

Assuming there is a failed drive in the RAID 5 logical drive, make it a point to replace the failed drive with a new, healthy drive to keep the logical drive working.

If, when trying to remove a failed drive you mistakenly remove the wrong drive, you will no longer be able to access the logical drive because you have inadequately failed another drive.

To prevent this from happening, the controller provides an easy way to identify the faulty drive. By forcing certain drive LEDs to light for a configurable period of time, the faulty drive can be identified, and thus reducing the chance of removing the wrong drive. This function is especially helpful in an installation site operating with hundreds of drives.

R/W LED

 

 

 

 

Flash Selected SCSI Drive

 

 

 

 

 

 

 

 

 

R/W LED

The Read/Write LED of the drive you selected will light steadily

 

 

 

 

for a configurable period of time, from 1 to 999 seconds.

 

 

 

 

 

 

LED Steadily ON

 

 

 

 

 

 

 

 

 

R/W LED

Flash All SCSI Drives

 

 

The Read/Write LEDs of all connected drives will

LED Steadily ON

R/W LED

light for a configurable period of time. If the LED of

 

 

the defective drive did not light on the “Flash

 

 

Selected SCSI Drive” function, use “Flash All SCSI

LED Steadily ON

 

 

 

Drives” to verify the fault. If the “Flash All SCSI

 

 

Drives” function is executed, and the defective drive’s

LED Steadily ON

 

 

 

LED still does not respond, it can be a drive tray

 

 

problem or the drive is dead.

LED Steadily ON

L E D

 

 

 

 

LED Steadily ON

L E D

Flash All but Selected Drives

 

 

 

L E D

Except the selected drive, the Read/Write LEDs of all

 

connected drives will light for a configurable period of time ranging

R /W

 

from 1 to 999 seconds. If an administrator can not be sure of the

L E D

exact location of specific drive, this function will help to indicate

 

 

where it is. This can prevent removal of the wrong drive when a

L E D

drive fails and is about to be replaced.

 

 

The drive identifying function can be selected from “Main

 

Menu”/”View and Edit SCSI Drives”/”Identify SCSI Drives.”

Functional Description

1-8

Page 30
Image 30
Compaq Infortrend Identifying Drives, Flash Selected Scsi Drive, Flash All Scsi Drives, Flash All but Selected Drives