Assigning a Name to a Logical Drive

Assigning a Name to a Logical Drive

Press ENT for two seconds to enter the Main Menu. Press or to select "View and Edit Logical Drives..," then press ENT.

Press or to select a logical drive, then press ENT.

Press or to select “Logical Drive Name," then press ENT.

Press or to change the character of the flashing cursor. Press ENT to move the cursor to the next space. The maximum number of characters for a logical drive name is 25.

View and Edit Logical Drives

LG0 RAID5 DRV=3 2012MB GD SB=1

Logical Drive

Name..

Enter LD Name:

_

Rebuilding a Logical Drive

If you want the controller to auto-detect a replacement drive, make sure you have the following items set to enabled:

1.Periodic Drive Check Time

2.Periodic Auto-Detect Failure Drive Swap Check Time

These two configuration options can be found under “View and Edit Configuration Parameters” ->Drive-Side SCSI Parameters”.

Press ENT for two seconds to enter the Main Menu. Press or to select "View and Edit Logical Drives..", then press ENT.

Press or to select the logical drive that has a failed member, then press ENT.

View and Edit Logical Drives

LG0 RAID5 DRV=3 2012MB FL SB=0

Press or to select “Rebuild Logical Drive," then press ENT.

Press ENT for two seconds to start rebuilding the logical drive.

The rebuilding progress will be displayed (as a percentage) on the LCD.

Rebuild Logical

Drive ..

Rebuild Logical

Drive?

Rebuilding 25% Please Wait!