A-6

View and Edit Configuration Parameters

Drive-side SCSI Parameters..

Disk Array Parameters..

Redundant Ctlr Configuration..

Controller Parameters..

Motor Spin-Up

Reset at Power-Up

Init Disk Access Delay -

SCSI I/O Timeout

Maximum Tag Count

Periodic Drive ChkTime -

Periodic SAF-TE ChkTime -

Periodic Drv Swap AutoChk -

SMART Mode -

Fibre Chl Dual Loop -

Rebuild Priority

Low

Normal

Improved

High ?

On LD Initialize Writes

On LD Rebuild Writes

On Normal Drive Writes

Enable/Disable Reset

at Power-Up

?

Enable/Disable Fibre Chl Dual Loop ?

Enable/Disable Motor

Spin-Up ?

Set Disk Delay

Time - No Delay to 75 seconds?

500 ms, 1, 2, 4, 6, Def (7), 8, 10 seconds ?

Disable, 1, 2, 4, 8, 16, 32, 64, 128 seconds ?

Disable, 1/2, 1, 2, 5, 10, 30 seconds ?

Disable, 50ms, 100ms, 200ms, 500ms, 1, 2, 5, 10, 20, 30, 60 seconds ?

Disable, 5, 10, 15, 30, 60 seconds ?

SMART Mode -

 

Disable?

 

Detect?

 

Perpetual Clone?

 

Clone + Replace?

Enable/Disable ?

RC Communication Channel-SCSI Bus/ Fibre Loops

 

 

Secondary Ctlr

Controller Name:

Enter Ctlr Name:

RS232 Enabled/Disabled..

Not Set

￿

 

LCD Title Disp -

 

 

Controller Name/Controller Logo?

Infortrend

View and Edit

Peripheral Device

View Peripheral Devices Status..

Set Peripheral Devices Entry..

Define Periph. Active Signal

Adjust LCD Contrast

Ctlr Peripheral Device Configuration..

Redundant Ctlr Function

UPS ...

Redundant Ctlr

Function Disabled

UPS Power

Status

Set UPS Fail

Sig Active Low/Active High

LCD Contrast :

❚❚❚❚❚❚❚------

View Ctlr Periph

Device Status..

Temperature and

Voltage Parms ..

Passwd Validation

Disable, 1, 2, 5 min, ...Always

Controller Password set

Timeout-Disabled?

Ctlr Unique

 

1 to 65535, must be different for each controller

ID- ****

 

SDRAM ECC -

 

 

 

Enable/Disable

?

 

 

Enable Redundant

 

 

Ctlr: Autocfg

?

 

 

Primary

?

 

 

Secondary ?

 

 

Enable/Disable UPS

 

 

Power Status

?

 

 

?

 

[+3.3V] 3.***V

 

 

 

[+5V] 5.***V

 

 

 

[+12V] 12.***V

 

Voltage Monitor

..

Operation Normal

 

 

[CPU] **.*°C

 

 

 

 

Temperature

 

[Board1] **.*°C

 

Monitor

..

[Board2] **.*°C

 

Trigger Threshold

in Safe Range

 

Upper Temp

 

for

 

Range *.*V-*.*V

3.3V Event

 

Event-Def (**C)

 

Range *°C-**°C

5V Event

 

 

 

Lower Temp

Input : ￿

12V Event

 

CPU Temp Event

Event-Def (**C)

 

Board Temp Event

Page 282
Image 282
Compaq Infortrend manual View and Edit Peripheral Device