Assigning a Logical Drive/Logical Volume to the Secondary Controller

Use or to select a SCSI ID and press [ENT] to confirm. The configuration change will take effect only after controller reset.

Set Sec. Ctlr ID:NA to ID: 6?

Host Channel

The process of creating Primary and Secondary IDs on host channels is basically the same.

In “View and Edit SCSI Channels”, press [ENT] to select a host channel. Use or to select “Set SCSI Channel ID”. A pre-configured ID will appear, press [ENT] to proceed. Use or to select “Add Channel SCSI ID” and then press [ENT] for two seconds on the “Primary” or ”Secondary Controller?” to proceed.

When prompted by this message, use or to select an ID. Press [ENT] to confirm and you will be prompted for resetting the controller.

A message will prompt to remind you to reset the controller. Press [ENT] to reset the controller or press [ESC] to move back to the previous menu. The change of ID will only take effect after controller reset.

CHL=0 ID=0

 

Primary

Ctlr ..

 

 

 

 

 

Add Channel

 

SCSI ID

..

 

 

 

Primary

Controller ?

Add CHL=0 ID=2 Primary Ctlr ?

Change Setting Do Reset Ctlr ?

Assigning a Logical Drive/Logical Volume to the Secondary Controller

A logical drive, logical volume, or any of its logical partitions can be assigned to the Primary or Secondary controller. By default, a logical drive is automatically assigned to the Primary controller. It can be assigned to the Secondary controller if the host computer is also connected to the Secondary controller.

Note that the partitions of a logical drive that has previously been assigned to the Secondary controller will automatically be assigned to the Secondary controller.

Press [ENT] for two seconds on the front panel of the Primary controller to enter the Main Menu.

Use or to navigate through the menus. Choose "View and Edit Logical Drives..," then press [ENT].

Create a logical drive or choose an existing logical drive, then press [ENT] to see the logical drive menu.

View and Edit Logical Drives

Redundant Controller

10-23

Page 236
Image 236
Compaq Infortrend manual Assigning a Logical Drive/Logical Volume to the Secondary Controller, Host Channel