Compaq Infortrend manual S.M.A.R.T. Support, Redundant Controller

Models: Infortrend

1 347
Download 347 pages 43.22 Kb
Page 289
Image 289

S.M.A.R.T. Support:

Copy & Replace Drive

Supported. User can choose to clone a member drive

 

before drive failure.

Drive S.M.A.R.T. Support

Supported, with intelligent error handling

 

implementations.

User selectable modes for

1.

Detect only

S.M.A.R.T.

2.

Perpetual Clone on detection of S.M.A.R.T. condition

 

3.

Clone + Replace

Redundant Controller:

Active-active redundant

Supported

controller

 

Synchronized cache

Supported. Through single or redundant, dedicated

 

synchronizing channels. Synchronized cache over Fibre

 

loops is supported.

 

Synchronized cache can be disabled when using write-

 

through mode in redundant controllers to prevent

 

performance trade-offs.

Write-back cache

Yes; with synchronized cache connection between

enabled in redundant

controllers.

controller mode

 

Automatic Failover

Yes for all PowerPC controllers (user's interaction

 

necessary)

Automatic Failback

Yes for all PowerPC controllers (user's interaction

 

necessary)

Fibre channel redundant

Supported.

controller

 

Controller Hot-Swap

! No need to shut down the failed controller before

 

replacing the failed controller. (Customer's design-in

 

hot-swap mechanism necessary)

 

! Support on-line hot-swap of the failed controller.

 

There is no need to reset or shutdown the failed

 

controller. One controller can be pulled out during

 

active I/Os to simulate the destructive controller failure.

 

(Customer's design-in hot-swap mechanism

 

necessary)

Redundant Controller

SentinelRAID: SCSI; RCC Reset signals built-in

Communication channel

EonRAID: Fibre channel(s); RCC cable necessary

Parity Synchronization

Supported.

in redundant controller

 

write-back mode to

 

avoid write-hole

 

B-6

Infortrend

Page 289
Image 289
Compaq Infortrend manual S.M.A.R.T. Support, Redundant Controller