Configuration Procedure

Enabling the S.M.A.R.T. Feature

Follow the procedure below to enable S.M.A.R.T. on all drives.

1.First, enable the “Periodic Drive Check Time” function. In \View and Edit Configuration Parameters\Drive-side SCSI Parameters\Periodic Drive Check Time, choose a time interval.

2.In \View and Edit Configuration Parameters\Drive-side SCSI Parameters\Drive Predictable Failure Mode <SMART>, choose one from “Detect Only,” “Detect, Perpetual Clone” and “Detect, Clone+Replace.”

Examining Whether Your Drives Support S.M.A.R.T.

To see if your drive supports S.M.A.R.T., follow the steps below:

3.Enable “S.M.A.R.T.” for your drives in the RAID system.

4.In “View and Edit SCSI Drives,” choose one drive to test to. Press [ENTER] on the drive, a sub-menu will appear.

5.Note that a new item “Predictable Failure Test” appears in the sub-menu. If the SMART” feature is not properly enabled, this item will not appear in the sub-menu.

9-7

Infortrend

Page 192
Image 192
Compaq Infortrend manual Configuration Procedure, Enabling the S.M.A.R.T. Feature