D-Link DHS-3224V manual Igmp Snooping State, Querier State, Robustness Variable, Query Interval

Models: DHS-3224V

1 162
Download 162 pages 31.12 Kb
Page 127
Image 127

D-Link DHS-3224V Switch User’s Guide

The user-changeable parameters for IGMP Snooping are as follows:

IGMP Snooping State

Select Enabled to implement IGMP Snooping.

Querier State

Choose V1 Querier for version 1 querier, V2 Querier for version 2

querier, or Non-Querier.

 

 

This entry field allows an entry of 2 to 255. Adjust this variable

Robustness Variable

according to expected packet loss. If packet loss is expected to be

high, the Robustness Variable should be increased to accommodate

 

 

increased packet loss.

Query Interval

The Query field allows an entry between 1 and 9,999 seconds and

defines the time between transmitting IGMP queries.

 

 

The Max-Response field allows an entry between 1 and 254 and

 

defines the maximum time allowed before sending a response report to

Max Response

a query measured in units of 1/10 of a second. This is used to adjust

the "leave latency", the time internal between the moment the last host

 

 

leaves a group and when the routing protocol is notified there are no

 

more members.

Age-out Timer

Displays the time the Switch waits between IGMP queries