D-Link DHS-3224V Switch User’s Guide

Figure7- 57. Packet Analysis window (Table)

The information is described as follows:

Time Interval

Select the desired setting between 1s and 60s, where “s” stands for seconds.

The default value is one second.

 

 

 

Record Number

Select number of times the Switch will be polled between 20 and 200. The

default value is 20.

 

 

 

64

The total number of packets (including bad packets) received that were 64

octets in length (excluding framing bits but including FCS octets).

 

 

 

65-127

The total number of packets (including bad packets) received that were

between 65 and 127 octets in length inclusive (excluding framing bits but

 

including FCS octets).

 

 

128–255

The total number of packets (including bad packets) received that were

between 128 and 255 octets in length inclusive (excluding framing bits but

 

including FCS octets).

 

 

256-511

The total number of packets (including bad packets) received that were

between 256 and 511 octets in length inclusive (excluding framing bits but

 

including FCS octets).

 

 

512-1023

The total number of packets (including bad packets) received that were

between 512 and 1023 octets in length inclusive (excluding framing bits but

 

including FCS octets).

 

 

1024-1518

The total number of packets (including bad packets) received that were

between 1024 and 1518 octets in length inclusive (excluding framing bits but

 

including FCS octets).

 

 

Show/Hide

Check whether or not to display 64, 65-127, 128-255, 256-511, 512-1023,

and 1024-1518 packets received.

 

 

 

Clear

Clicking this button clears all statistics counters on this window.

 

 

View Table

Clicking this button instructs the Switch to display a table rather than a line

graph.

 

 

 

View Line Chart

Clicking this button instructs the Switch to display a line graph rather than a

table.

 

 

 

132

Page 146
Image 146
D-Link DHS-3224V manual 65-127, 128-255, 256-511, 512-1023, 1024-1518