View Comm Settings Menu

The View Comm Settings menu lets you view the current settings for the communication ports, including the IP, subnet mask, and gateway addresses of the unit, the MAC (Media Access Code or hardware) address, the Dynamic Host Configuration Protocol (DHCP) status, and the serial port baud rate and type.

NOTE: None of the settings can be changed from this menu; to make adjustments, use

the Edit Comm Settings menu (see “Edit Comm Settings Menu”).

The flow diagram below shows the screens and the settings that can be viewed from this menu.

Advanced

Configuration

Menu

View Comm

Settings

Next

Next

 

 

Serial Port

 

Next

 

 

MAC Address

 

Next

 

 

9600

RS232

 

 

 

0005A605CDC7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Serial Port

 

 

 

 

MAC Address

 

 

 

 

 

View baud rate and port

 

 

 

View Media Access Code

 

 

 

 

 

protocol.

 

 

 

(MAC) hardware address.

 

 

IP Address

 

 

 

Subnet Mask

 

 

192.168.254.254

 

Next

 

255.255.000.000

 

Next

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DHCP Mode

Off

DHCP Mode View Dynamic Host Configuration Protocol (DHCP) On/Off status.

Next

Gateway Address 000.000.000.000

IP Address

Subnet Mask

View unit IP address.

View subnet mask IP address.

Gateway Address

View gateway IP address.

Figure 20. View Comm Settings Menu

Edit Comm Settings Menu

This menu lets you make changes to the serial port configuration, IP addresses, and the DHCP mode. Although the Edit Comm Settings menu has almost all the same screens as the View Comm Settings menu, it is accessed differently.

NOTE: You can access the Edit Comm Settings menu from any other menu or from the

default cycle.

To display the Edit Comm Settings menu:

1.Press and hold the Next button.

2.While holding the Next button, press the Detail and Color/Tint buttons simultaneously.

3.Hold all three buttons until the Edit Comm Settings screen is displayed (approximately

2 seconds).

If no activity occurs within 30 seconds, the DVS saves all settings and returns to the default cycle.

DVS 510 Series • Operation 34

Page 40
Image 40
Extron electronic DVS 510 SA manual View Comm Settings Menu, Edit Comm Settings Menu