Symbol Definitions for IP-specific SIS Commands

= Space

] =

Carriage return with line feed

}= Carriage return with no line feed

= Pipe (vertical bar) character. For URL-encoded commands, has the same function as ]. E = Escape

W= For URL-encoded commands, has the same function as E

14, 24, 27, 28 = Superscripts indicate the error message displayed if the command is entered incorrectly or with invalid parameters (see “Error Response References” on page 50).

X!

=

Input selection

1 through 10

X1)

=

On and off

0 = Off or disable

 

 

 

1 = On or enable

X7!

=

Port number

01–99(represented as two ASCII characters with

 

 

 

leading zero if required)

X7@

=

Command data section

Factory default name (model name + last 3 pairs of

 

 

 

MAC address)

X7#

=

GMT offset

–12.0through +14.0. Represents hours and minutes

 

 

 

offset from Greenwich mean time (GMT).

X8!

=

Firmware version number

n.nn (listed to two decimal places)

X8@

=

Unit name

Up to 24 characters: alphabetical (A–Zor a–z), digits

 

 

 

(0–9), or hyphen (-).

NOTES: The following characters are invalid or not recommended in names:

 

 

{space} + ~ , @ = ` [ ] { } < > ‘ ’ “ ” ; : \ and ?.

 

 

The first character must be alphabetical.

 

 

The last character must not be a hyphen.

X8#

X8$

X8&

=

Local date and time format

For setting:

 

 

In the format MM/DD/YY•HH:MM:SS

 

 

MM = month: 10 (January) through 12 (December)

 

 

DD = 01 through 31

 

 

YY = 00 through 99

 

 

HH = 00 through 23

 

 

MM = 00 through 59

 

 

SS = 00 through 59

 

 

For reading:

 

 

In the format Day,•DD•Mmm•YYYY•HH:MM:SS:

 

 

Day = weekday: Mon through Sun

 

 

DD = 01 through 31

 

 

Mmm = month: (Jan through Dec)

 

 

YYYY = year: 2000 through 2099

 

 

HH = hour: 00 through 23

 

 

MM = minutes: 00 through 59

 

 

SS = seconds: 00 through 59

=

IP address

nnn.nnn.nnn.nnn

 

 

(Leading zeros in each of the four fields are optional

 

 

for setting values and are suppressed in returned

 

 

values.)

 

 

Factory default IP address: 192.168.254.254

 

 

Default broadcast IP address: 255.255.255.255

= Time (in 10-ms increments) to wait

10 through 32767

 

for characters to arrive at a serial

Default = 10, or 100 ms

 

port before terminating the

 

 

connection

 

DVS 510 Series • Remote Configuration and Control 67

Page 73
Image 73
Extron electronic DVS 510 SA manual Symbol Definitions for IP-specific SIS Commands, X7#, X8# X8$