Command

ASCII Command

Response

Additional Description

(Host to Scaler)

(Scaler to Host)

 

 

 

 

 

 

 

IP Setup Commands (continued)

 

 

 

Set verbose mode

E X9@ CV }

Vrb X9@ ]

Set verbose mode X9@. For X9@:

 

 

 

0

= verbose mode and tagged

 

 

 

1

responses disabled

 

 

 

= verbose mode

 

 

 

2

= tagged responses for queries

 

 

 

3

= verbose mode and tagged

 

 

 

 

responses for queries

Default is 0 for Telnet connections and 1 for RS-232 or RS-422 control.

NOTES: If verbose mode is enabled (modes 1 and 3), you are shown all actions (commands) initiated by other users via the web, RS-232, RS-422, or the front panel. (This does not include information requests.)

If tagged responses are enabled (modes 2 and 3), the unit responds to all read or view commands with the command text as well as the value or information requested. For example, the view name command E CN } returns Ipn X8@ ] instead of the name only (X8@).

View verbose mode Set broadcast mode

Set broadcast mode to default address

Clear broadcast mode View broadcast mode

Set broadcast port and MAC address

Set event target IP address

Set event target TCP port Set event target IP address

E CV}

X9@ ]

 

E X12%,X8$ }

Bmd X12%,X8$ ]

 

E X12% EB }

Bmd X12%,X8$ ]

 

E 0EB }

Bmd000,X8$ ]

 

E EB }

Bmd X12%,X8$ ]

 

E X7@ * X13# * X13$ PB }

 

 

 

Bpt X7@ * X8( ]

X7@ = UDP outgoing port

 

 

X13#*X13$ = MAC address for

 

 

UDP unicast transmissions

E X10$,X8$ ID }

Edi X10$ * X8$ * X7@ ]

 

 

 

X10$ = event number (The event

 

 

must be running.)

 

 

X7$ = 0–99

E X10$,X7@ ID }

Edi X10$ * X8$ * X7@ ]

 

E X10$ ID }

X8$ * X7@ ]

 

Password and Security Settings

Set administrator password24

E X10@ CA }

Ipa X10( ]

Set administrator access

 

 

 

password X10@.

X10@ = 4 to 12 alphanumeric characters. The password is case sensitive. Special characters (spaces or symbols) are not allowed.

X10( = password. If a password exists, the unit responds with the password (RS-232 or RS-422 connection) or 4 asterisks (****) (IP connection). If there is no password, the response is empty.

View administrator password24

E CA }

X10( ]

 

Reset (clear) administrator24

E CA }

Ipa ]

Clear or remove all passwords

password

 

 

(administrator and user).

DVS 510 Series • Remote Configuration and Control 73

Page 79
Image 79
Extron electronic DVS 510 SA manual Password and Security Settings