X8*

=

Time (in 10-ms increments) to wait

 

 

between characters before

 

 

terminating the connection

X8(

=

Hardware (MAC) address

X9)

=

Subnet mask

X9! = Message length, delimiter value, or byte count (via the serial port). (This parameter is optional.)

X9@ = Verbose mode

2 through 32767 Default = 2, or 20 ms

00-05-A6-xx-xx-xx

nnn.nnn.nnn.nnn

(Leading zeros in each of the four fields are optional for setting values and are suppressed in returned values.

Factory default subnet mask: 255.255.0.0

nL = Length of message to be received. For the length, n = byte count (1 through 32767; default is 0).

nD = Delimiter value

0 = clear or none (default for Telnet connection)

1 = verbose mode (default for RS-232 and RS-422)

2 = tagged responses for queries

3 = verbose mode and tagged responses for queries

NOTES: If verbose mode is enabled (modes 1 and 3), you are shown all actions (commands) initiated by other users via the web, RS-232/RS-422, or the front panel. (This does not include information requests.)

If tagged responses are enabled (modes 2 and 3), the unit responds to all read or view commands with the command text as well as the value or information requested For example, the View Name command E CN } returns Ipn X8@ ] instead of the name only (X8@).

X9#

=

Priority status for receiving timeouts

1

= use Send data string parameters (if they

 

 

 

 

exist) (default).

 

 

 

2

= use Configure receive timeout command

 

 

 

 

parameters instead.

X9%

=

Baud rate

9600 (default), 19200, 38400, or 115200

X9^

=

Parity

Odd, Even, None (default), Mark, Space (Only the

 

 

 

first letter is required.)

X9&

=

Data bits

7 or 8 (default)

X9*

=

Stop bits

1

(default) or 2

X9(

=

Port type

0

= RS-232 (default)

 

 

 

1

= RS-422

X10) =

Flow control

Hardware, Software, None (default) (Only the first

 

 

 

letter is required.)

X10! =

Data pacing

Specified in milliseconds between bytes:

 

 

 

0000 through 1000 (default = 0 ms)

X10@ =

Password

12 characters maximum

NOTE:

The following characters are invalid in passwords:

 

 

{space} + ~ , @ = ` [ ] { } < > ‘ ’

“ ” ; : \ and

?.

X10# =

Daylight saving time

0

= off or ignore

 

 

1

= USA (begins second Sunday in March and ends first

 

 

2

Sunday in November.)

 

 

= Europe (Begins last Sunday in March and ends

 

 

3

last Sunday in October.)

 

 

= Brazil (Begins third Sunday in October and ends

 

 

 

third Sunday in February.)

X10$ =

Event number

0 through 99 (The event must be running.)

DVS 510 Series • Remote Configuration and Control 68

Page 74
Image 74
Extron electronic DVS 510 SA manual X9#, X10 =, X10! =, X10# =, X10$ =