Extron electronic DVS 510 SA manual Event Control

Models: DVS 510 SA

1 128
Download 128 pages 22.74 Kb
Page 83
Image 83

Command

ASCII Command

Response

Additional Description

(Host to Scaler)

(Scaler to Host)

 

 

Event Control

 

 

 

View event buffer memory27

E X10$,X10%,X10^,X10& E }

 

 

 

X12) ]

 

Write event buffer memory24,27

E X10$,X10%,X10^,X10* X10& E }

 

 

 

Evt X10$,X10%,X10^,X10* ]

NOTE: The response to the Write Event command is padded with leading zeros for X10$ and X10^.

X10$ = 5 digits; X10^ = 10 digits.

 

 

Write string to event buffer

E string * X10$,X10%,X10^ FE }

 

memory24,27

 

 

 

Evt X10$,X10%,X10^,string ]

NOTES: F must be capitalized to read and write strings to event buffer memory.

The response to the Write String command is padded with leading zeros for X10$ and X10^. X10$ = 5 digits; X10^ = 10 digits.

The Write String command expects a string preceded by E. Strings returned by the device (read or write response) are binary (non-escaped) data.

View string from event buffer memory27

Start events24,27 Stop events24,27

Query the number of events running

E X10$,X10%,X10^,X11) FE }

 

String

 

E 1AE }

Ego ]

 

E 0AE }

Est ]

 

E AE }

nnnnn ]

Response is a 5-digit number.

 

In Verbose Mode:

Telnet text responses:

 

Enm nnnnn ]

event0 starting loc,

 

 

length ]

 

 

event1 starting loc,

 

 

length ]

DVS 510 Series • Remote Configuration and Control 77

Page 83
Image 83
Extron electronic DVS 510 SA manual Event Control