Command

ASCII Command

Response

Additional Description

(Host to Scaler)

(Scaler to Host)

 

 

 

 

 

 

 

 

 

 

Presets (continued)

 

 

 

Input Presets

 

 

 

Recall input preset

2 * X2^ .

2 Rpr X2^ ]

Recall input preset X2^.

Save input preset

2 * X2^ ,

2 Spr X2^ ]

Save the parameters of the current input

 

 

 

to preset X2^ (for saved parameters, see

 

 

 

Input presets” under “Symbol

 

 

 

Definitions for DVS 510 Series SIS

 

 

 

Commands”).

 

 

 

 

Input Preset Name

 

 

 

Write preset name

E X2^ , X1$ NP }

Nmp X2^ , X1$ ]

Set name of preset X2^ to X1$. The

 

 

 

command character is a comma. Presets

 

 

 

can have up to 16 characters.

NOTE: The following characters are invalid in input preset names:

 

~ @ = ` [] {} <> ’ ‘ “ ” ; (semicolon) : (colon)

/ \ ? and space.

View preset name

E X2^ NP }

X1$ ]

View the name of input preset X2^.

NOTE: To clear an input preset name, enter one space character for X1$.

Auto Memories

 

 

 

Enable

E 1 AMEM }

Amem 1 ]

Enable auto memories to automatically

 

 

 

recall the previous settings for the

 

 

 

incoming signal (default).

Disable

E 0 AMEM }

Amem 0 ]

Disable auto memories. Input presets

 

 

 

must be manually recalled to configure

 

 

 

the input.

View setting

E AMEM }

X1) ]

View the status of auto memories.

Advanced Configuration

 

 

Test Pattern

 

 

 

Set test pattern

E X2) TEST }

Test X2) ]

Select test pattern X2).

View test pattern

E TEST }

X2) ]

View the current test pattern.

Freeze

 

 

 

Set freeze

1 F

Frz 1 ]

Freeze the selected input.

Set freeze

0 F

Frz 0 ]

Unfreeze the selected input.

View

F

X1) ]

Show the freeze status (1= on, 0= off).

RGB Delay Time

 

 

 

Set RGB delay

E X3& VDLY }

Vdly X3& ]

Set the time the DVS will delay displaying

 

 

 

the new input to X3&.

View setting

E VDLY }

X3& ]

View the RGB delay setting.

NOTE: X1) = Auto memories or freeze status

0 = disabled, 1 = enabled

X1$ = Input preset name

Up to 16 characters; no special characters

X2) = Test pattern

0 through 13 (see “Test pattern” under “Symbol Definitions for

X2^ = Input preset number

DVS 510 Series SIS Commands” for the available test patterns).

1 through 128

X3& = RGB delay amount

0 through 50 in 0.1-second increments. Default is 05 (0.5 seconds).

 

DVS 510 Series • Remote Configuration and Control 63

Page 69
Image 69
Extron electronic DVS 510 SA manual X2 , X1$ NP Nmp X2 , X1$, Advanced Configuration, X2 Test, X3& Vdly