Command

ASCII Command

Response

Additional Description

(Host to Scaler)

(Scaler to Host)

 

 

 

 

 

Password and Security Settings (continued)

 

 

Set user password14

E X10@ CU }

Ipu X10( ]

Set user access password X10@.

X10@ = 4 to 12 alphanumeric characters. The password is case sensitive. Special characters (spaces or symbols) are not allowed.

X10( = password. If a password exists, the unit responds with the password (RS-232 or RS-422 connection) or 4 asterisks (****) (IP connection). If there is no password, the response is empty.

NOTE: A user password cannot be assigned if an administrator password does not exist. Entering a password when the DVS has not been configured yields an E14 error response from the scaler. If the administrator password is cleared (removed), the user password is removed also.

View user password

E CU }

X10( ]

 

Reset (clear) user password

E CU }

Ipu ]

Clear or remove the user

 

 

 

password.

Query session security level

E CK }

X11* ]

 

 

 

In verbose mode:

 

 

 

Pvl X11* ]

 

 

 

 

 

Remap Port Destinations

 

 

 

Set Telnet port map24

E X7@ MT }

Pmt X7@ ]

X7@ = Telnet port number

Reset Telnet port map24

E 23MT }

Pmt00032 ]

 

Disable Telnet port

E 0MT }

Pmt00000 ]

 

View Telnet port mapping

E MT }

X7@ ]

 

NOTES: Duplicate port number assignments are not permitted (for example, the Telnet and web mapping cannot be the same). An E13 (invalid parameter) error code results.

Remapping of the port number other than to reset it to defaults 80 or 23 or to disable it by resetting it to 0 can be done only to ports numbered 1024 or higher.

Set web port map24

E X7@ MH }

Pmh X7@ ]

Reset web port map24

E 80MH }

Pmh00080 ]

Disable web port24

E 0MH }

Pmh00000 ]

View web port map24

E MH }

X7@ ]

Set Direct Access port map24

E X7@ MD }

Pmd X7@ ]

Reset Direct Access port map24

E 2001MD }

PMD02001]

Disable Direct Access port map24

E 0MD }

PMD00000 ]

View Direct Access port map24

E MD }

X7@ ]

DVS 510 Series • Remote Configuration and Control 74

Page 80
Image 80
Extron electronic DVS 510 SA manual X10@ CU Ipu, Remap Port Destinations