DVS 510 Series • Remote Configuration and Control 52
X1$ = Input preset name 16 characters maximum; ASCII characters 23 through
126 only
X1% = Picture adjustment 0 through 127
X1^ = H and V position Value based on the current output resolution
X1& = H and V size Value based on the current output resolution
X1* = Zoom 100% through 200%
X1( = Pan (value depends on the
zoom setting)
X2) = Test pattern 0 = None 7 = White Field
1 = Color Bars 8 = Crop
2 = Crosshatch 9 = 1.33 Aspect Ratio
3 = 4x4 Crosshatch 10 = 1.78 Aspect Ratio
4 = Grayscale (16 level) 11 = 1.85 Aspect Ratio
5 = Ramp 12 = 2.35 Aspect Ratio
6 = Alternating Pixels 13 = Blue Mode
X2! = Output resolution and EDID 0 = automatic (match current scaler output resolution)
emulation (default)
10-90 = (see the EDID table below)

SIS Variables for EDID Resolution and Refresh Rate Combination

Resolution 23.98 Hz 24 Hz 25 Hz 29.97 Hz 30 Hz 50 Hz 59.94 Hz 60 Hz 75 Hz
640 x 480 10 11 12
800 x 600 13 14 15
852 x 480 16 17 18
1024 x 768 19 20 21
1024 x 852 22 23 24
1024 x 1024 25 26 27
1280 x 768 28 29 30
1280 x 800 31 32 33
1280 x 1024 34 35 36
1360 x 765 37 38 39
1360 x 768 40 41 42
1365 x 768 43 44 45
1365 x 1024 49 50 51
1366 x 768 46 47 48
1400 x 1050 55 56
1440 x 900 52 53 54
1600 x 1200 59 60
1680 x 1050 57 58
1920 x 1200 61 62
480p 63 64
576p 65
720p 66 67 68 69 70 71
1080i 72 73 74
1080p 75 76 77 78 79 80 81 82
2048 x 1080 83 84 85 86 87 88 89 90

Figure 29. SIS Commands EDID Table