DVS 510 Series • Remote Configuration and Control 51
ASCII to Hex Conversion Table
Space
Figure 28. ASCII to Hexadecimal Character Conversion Table
NOTE: Upper- and lowercase text can be used interchangeably except where noted.
Symbol Definitions for DVS 510 Series SIS Commands
= Space
] = Carriage return with line feed
} = Carriage return with no line feed
| = Pipe (vertical bar) character. For URL-encoded commands, has the same function as }.
E = Escape
W = For URL-encoded commands, has the same function as E
14, 24, 27, 28 = Superscripts indicate the error message displayed if the command is entered
incorrectly or with invalid parameters (see “Error Response References” on the
previous page).
X! = Input selection 1 through 10
X@ = Output selection 1 = DVI
2 = Top VGA connector
3 = Bottom VGA connector
X# = Input video format 1 = RGB 5 = S-video
2 = YUVp/HDTV 6 = Composite
3 = RGBcvS 7 = DVI
4 = YUVi
X$ = H start 0 through 255
X% = V start 0 through 255
X^ = Pixel phase 0 through 31
X& = Total pixels (±512 of default
value for high resolution video
and ±256 of the default value for
low resolution video)
X* = Active pixels (±512 of the default
value for high resolution video
and ±256 of the default value for
low resolution video)
X( = Active lines (±256 of default value)
X1) = On and off 0 = Off or disable
1 = On or enable
X1! = Input standard 0 = No signal 3 = NTSC 4.43
1 = NTSC 3.58 4 = SECAM
2 = PAL
= Not applicable (occurs when input is set to RGB or
YUVp/HDTV)
X1@ = Internal temperature (in degrees Celsius)