6.Double-click on <double click to set> in the New Firmware File column, or select New Firmware for Selected Devices from the File menu.

Figure 36. Firmware Loader Window

The Choose Firmware File window opens.

Figure 37. Choose Firmware File Window

7.Navigate to the new firmware file, which has a .s19 extension, and double-click it. The Choose Firmware File window closes.

CAUTION: Valid firmware files must have the file extension .s19. A file with any other extension is not a firmware upgrade for this product and could cause the DVS to stop functioning.

NOTES: The original factory-installed firmware is permanently available on the

DVS 510. If the attempted firmware upload fails for any reason, the scaler

reverts to the factory-installed firmware.

When downloaded from the Extron website, the firmware is placed in a folder at C:\Program Files\Extron\Firmware\DVS 510 or C:\Program Files (x86)\Extron\Firmware\DVS 510 (for Windows 7).