15.2.11 Interrupt Mask Register (0x14)IMR
The write-only IMR register selects corresponding bits in the ISR that cause an interrupt.
If one ISR bit is set and the corresponding IMR bit is also set, the internal interrupt output is asserted.
If the corresponding bit in IMR is 0, the state of the ISR bit has no effect on the interrupt output. The IMR does not mask reading
the ISR.
4 TxEMP/
URERR
UART / SI R—TxEMP
This bit is identical to the URERR bit in the SR register.
other Modes—Underrun Error
This bit is identical to the URERR bit in the SR register. To clear this interrupt use the reset
error status command in the CR register.
5DBUAR T / SIR—Delta Break
Receiver detect an Delta Break state.
other Modes—Reserved
6RxRDY
FFULL
Rx FIFO over threshold. If MR1[1] =1, then this bit is identical to the FFULL bit in the SR
register. If MR1[1] =0, then this bit is identical to the RxRDY bit in the SR register.
7 TxRDY Transmitter ready - identical to the TxRDY bit in the SR register
8DEOFMIR / FIR—Detect End of Frame
0 = Rx did not receive an EOF after the last read SR command.
1 = Rx received the EOF in the frame. In this case, the interrupt and request can be
asserted even if the Rx FIFO number is less than the threshold and MR1[1]=1.
To clear this interrupt use the reset error status command in the CR register.
other Modes—Reserved
9 Error Error
This bit is identical to the Error bit in the SR register. To clear this interrupt use the reset
error status command in the CR register.
10:11 — Reserved
12 CMD_SEND Enhanced AC97 Mode—Command Send ready
This bit is identical to the CMD_SEND bit in the SR register. To clear this interrupt use the
reset error status command in the CR register.
other Modes—Reserved
13 DATA_OVR Enhanced AC97 Mode—Receive Data Overwrite
This bit is identical to the DATA_OVR bit in the SR register. To clear this interrupt use the
reset error status command in the CR register.
other Modes—Reserved
14 DATA_VALID Enhanced AC97 Mode—Received Status Data
This bit is identical to the DATA_VALID bit in the SR register. To clear this interrupt use the
reset error status command in the CR register.
other Modes—Reserved
15 UNEX_RX_
SLOT
Enhanced AC97 Mode—Unexpected RX Slots detect
This bit is identical to the UNEX_RX_SLOT bit in the SR register. To clear this interrupt use
the reset error status command in the CR register.
other Modes—Reserved
Bit Name Description