Product Description

SECTION 1

Features and Options

Product Description

The Fire-LiteMS-9200UDLS is a combination FACP (Fire Alarm Control Panel) and DACT (Digital Alarm Communicator/Transmitter) all on one circuit board. This compact, cost effective, intelligent addressable control panel has an extensive list of powerful features. The combination of Fire-Lite’s newer series devices and legacy 300 Series devices, along with the MS-9200UDLS FACP, offer the latest in fire protection technology. The power supply and all electronics are contained on a single circuit board housed in a metal cabinet, providing a complete fire control system for most applications. Optional modules, which plug into the main circuit board, are available for special functions. Available accessories include LED, graphic and LCD annunciators, reverse polarity/city box transmitter, local and remote upload/download software and remote power expansion.

The integral DACT transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. It also allows remote and local programming of the control panel using the PK-CD Upload/Download utility. In addition, the control panel may be programmed or interrogated off-site via the public switched telephone network. Any personal computer with Windows95 or greater, and compatible modem with a speed of 14.4 kbps or faster and Fire•Lite Upload/ Download software kit PK-CD, may serve as a Service Terminal. This allows download of the entire program or upload of the entire program, history file, walktest data, current status and system voltages.

MS-9200UDLS is used in this manual to refer to both the MS-9200UDLS and the MS- 9200UDLSE FACPs (Fire Alarm Control Panels).

Inventory

When the MS-9200UDLS shipment is received, check to make certain that all parts have been included in the shipment. The MS-9200UDLS shipment should consist of one of each of the following:

main circuit board with display backbox with door

plastic bag containing screws, cables, key, etc. manual

1.1Features and Options

New LiteSpeed™ polling protocol for faster SLC response time

SLC operates up to 10,000 ft. (3,000 m) with twisted, unshielded wire (refer to "Wire Requirements" on page 178)

Built-in DACT (Digital Alarm Communicator/Transmitter)

Single addressable SLC loop which meets NFPA Style 4, 6 and 7 requirements

198 addressable device capacity (99 detectors and 99 control/relay/monitor modules)

99 software zones

Onboard NACs (Notification Appliance Circuits) which can be configured as four Style Y (Class B) or two Style Z (Class A) circuits - special application

3.0 amps total power for NACs and 24 VDC special application auxiliary power outputs expandable to 6.0 amps

3.6 amps total system power (includes battery charger) expandable to 6.6 amps

Two programmable relay outputs and one fixed trouble relay

Synchronization output for remote power supply applications (special application)

Built-in Programmer

12

MS-9200UDLS PN 52750:A 11/04/05