MS-9200UDLS, MS-9200UDLSE manual
Notes
1
4
188
188
Download
188 pages, 2.42 Mb
Notes
4
MS-9200UDLS
PN 52750:A 11/04/05
Contents
Fire Alarm Control Panel
IMPORTANT
Page
Page
Notes
SECTION 1: Product Description
SECTION 2: Installation
SECTION 3: Programming
Page
SECTION 4: Operating Instructions
SECTION 5: Central Station Communications
SECTION 6: Remote Site Upload/Download
SECTION 7: Power Supply Calculations
APPENDIX A: Software Zones
APPENDIX B: Default Programming
NFPA Standards
Underwriters Laboratories Documents:
Other:
Fire-LiteDocuments:
Basic System Connections
Page
Product Description
AC Power - TB11
Page
EIA-485(TERM) or EIA-232(ACS) - TB8
EIA-485(ACS) - TB9
1.2.1 Current Availability
Figure 1.1 Current Availability
HONEYWELL LIFE SAFETY
SYSTEM ALL NORMAL 10:00A
LCD Display
LED Indicators
Key Panel
SLC Communication Loop
Output Circuits
NAC (Notification Appliance Circuits)
Relays
Main Circuit Board
Cabinet
Transformer Assembly
Batteries
1.6.1 Intelligent Addressable Detectors: Newer Series
1.6.2 Intelligent Addressable Modules: Newer Series
1.6.3 300 Series Intelligent Addressable Devices
1.6.4 Addressable Device Accessories
End-of-LineResistor Assembly
Power Supervision Relay
4XTMF Transmitter Module
1.8.1 PK-CDProgramming Utility
1.8.2 Dress Panel
1.8.4.1CHG-75Battery Charger
1.8.4.2 CHG-120FBattery Charger
1.8.5 Annunciators
ACS Series LED Zone Type Annunciators
ACM-16ATF
AEM-16ATF
AFM-16ATF
LCD-80FRemote Fire Annunciator
LDM Series Lamp Driver Modules (Graphic Annunciator)
1.10.1Telephone Circuitry
1.10.2Digital Communicator
MS-9200UDLS
US:1W6AL00B9200UD
0.0B
1.10.3Telephone Company Rights and Warnings
1.10.4For Canadian Applications
CAUTION
Installation
Figure 2.2 MS-9200UDLSMain Board/Chassis Installation
Figure 2.3 MS-9200UDLSCabinet Mounting
Page
WARNING:
2.3.1 AC Power and Earth Ground Connection
2.3.2 Battery Power
2.3.3 Special Application DC Power Output Connection
Figure 2.5 Special Application Power Outputs - 24 VDC
TB7 TB5 TB6
Figure 2.6 Relay Terminals
2.5.1 Configuring NACs
Figure 2.7 NAC Configuration Using NACKEY
2.5.2 Style Y (Class B) NAC Wiring
Figure 2.8 NAC Style Y (Class B) Wiring
2.5.3 Style Z (Class A) NAC Wiring
Figure 2.9 NAC Style Z (Class A) Wiring
Figure 2.10 Remote Sync Output
Figure 2.11 Typical UL Power-limitedWiring Requirements
*Ferrite Bead Installation
Figure 2.12 DACT Installation
Figure 2.13 Wiring Phone Jacks
WARNING
MS-9200UDLSKeypad/Display Removal
Figure 2.14 Keypad/Display Removal
2.9.1 4XTMF Transmitter Module Installation
Figure 2.16 4XTMF Connectors to MS-9200UDLSConnectors
2.9.2 Printer/PC
CAUTION
Installation
Figure 2.17 Serial Printer and Computer Connections
Printer Configuration
2.9.3.1ACM-8RFRelay Control Module
2.9.3.2 ACS and AFM Series Annunciators
Programming
Autoprogramming Feature
SYSTEM ALL NORMAL
10:00A
1=READ STATUS MODE
2=PROGRAMMING MODE
User Programming Levels
TROUBL IN SYSTEM
NO DEVICES INSTALLED 09:03A
1=READ STATUS MODE 2=PROGRAMMING MODE 3=MANUAL DIAL MODE
PROGRAMMING
ENTER PASSWORD
Master
Maintenance
Programming Screen #1
PROGRAMMING 1=LOOP SETUP 2=SYSTEM SETUP 3=VERIFY LOOP
Programming Screen #2
PROGRAMMING 1=HISTORY 2=WALKTEST
3=OPTION MODULES
3.6.1 Autoprogram
AUTOPROGRAM
AUTOPROGRAMMING
PLEASE WAIT
Autoprogram Progress Screen
3.6.2.1 Detector Programming
DETECTOR#
IS ADDED
3.6.2.1.2 Delete Detector
DELETE DETECTOR
Delete Detector Screen
NO DETECTOR
INSTALLED
Edit Detector Screen #1
TROUBL SMOKE(PHOTO) <ADJ><NOUN
ZNNN
EDIT DETECTOR 1D017
1=ENABLED YES 2=TYPE SMOKE(PHOTO) 3=VERIFICATION OFF
Edit Detector Screen #2
1=WALKTEST NO
2=PASNO
DETECTOR TYPE 1=SMOKE(PHOTO) 2=USER-DEFINED-13=SMOKE (ION)
Detector Type Screen #1
Verification
Walktest
PAS
Pre-signal
Zone Assignment
ZONE ASSIGNMENT
Z00 Z** Z** Z** Z
Zone Assignment Screen
Noun/Adjective
1=NORTH
1=3RD
2=SOUTH
2=4TH
3=EAST
1=BASEMENT
1=KITCHEN
2=BOILER RM
2=LOBBY
3=CLASSROOM
Description
DESCRIPTION 1D002 1=NOUN/ADJECTIVE
Adjective/Noun Screen
Recall/Increment Function
3.6.2.2Module Programming
MODULE#
Add Module Screen #3
3.6.2.2.2 Delete Module
DELETE MODULE ENTER MODULE#
Delete Module Screen
NO MODULE
TROUBL MONITOR <ADJ><NOUN
*1M012
NORMAL MONITOR <ADJ><NOUN
ZNNN W 1M012
ZNNN 1M012
EDIT MONITOR 1M012
1=ENABLED YES 2=TYPE MONITOR
Edit Monitor Screen #2
1=PRE-SIGNALNO
Enable/Disable Module
Type Monitor
MONITOR TYPE 1=PULL-STATION 2=USER-DEFINED-1
3=WATERFLOW
Monitor Type Screen #1
Table 3.1 Monitor Types
MON ZONE ASSIGN
1=FLOOR
2=FLOOR
1=GARAGE 2=HALLWAY
1=ZONE
DESCRIPTION 1M012 1=NOUN/ADJECTIVE
3.6.2.2.4Edit Module Screen for Control Modules
NORMAL CONTROL <ADJ><NOUN
SW 1M002
Edit Control Screen #1
EDIT CONTROL
1=ENABLED YES 2=TYPE CONTROL
3=SILENCEABLE YES
Edit Control Screen #2
Edit Control Screen #3
CONTROL TYPE 1=BLANK 2=BELL-CIRCUIT 3=HORN-CIRCUIT
Control Type Screen #1
Silenceable
Page
Page
DESCRIPTION 1M002 1=NOUN/ADJECTIVE
3.6.3.1 Enable
3.6.3.2 Disable
3.6.3.3 Zone 97, 98 and
3.6.3.4 Zones Installed
3.6.3.5 Zones Enabled
3.6.3.6 Zones Disabled
3.6.3.7 Zone Type
3.6.3.8 Zones Available
3.6.4.1 Style
3.6.4.2 Loop Protocol
3.6.5 System Setup
SYSTEM SETUP
1=TROUBLE REM OFF 2=BANNER 3=TIME-DATE
System Setup Screen #1
SYSTEM SETUP 1=TIMERS
3.6.5.1 Trouble Reminder
3.6.5.2 Banner
3.6.5.3 Time-Date
WEEK
3.6.5.4 Timers
Pre-signalDelay
PRESIGNAL DELAY
Pre-signalDelay Screen
3.6.5.4.3 Waterflow Delay
WATERFLOW DELAY
3.6.5.5 NAC (Notification Appliance Circuit)
2=TYPEBELL
NAC Screen #1
1=AUTO SILENCE
2=CODING
TEMPORAL
3.6.5.5.2 Type
NAC TYPE
1=BELL
2=HORN
3=STROBE
3.6.5.5.4 Auto Silence
AUTO SILENCE 1=NO
2=5 MINUTES 3=10 MINUTES
Auto Silence Screen #1
AUTO SILENCE 1=15 MINUTES 2=20 MINUTES 3=25 MINUTES
3.6.5.5.5.1 Two Stage Operation
3.6.5.5.6 Zone
Zone Screen
3.6.5.5.7 Silence Inhibited
3.6.5.5.8 Sync Type
NAC SYNC TYPE 1=SYSTEM SENSOR 2=WHEELOCK 3=GENTEX
3.6.5.6 Relays
3.6.5.7 Canadian Option
3.6.5.8 Waterflow Silenceable
3.6.7.1 View Events
3.6.7.2 Erase History
3.6.8 Walktest
WALKTEST
1=SILENT
2=AUDIBLE
3=VIEW RESULT
3.6.9.1 Annunciators/UDACT
3.6.9.2 Onboard DACT
3.6.9.2.2 Primary Phone
PRIMARY PHONE LINE
1=TYPE TOUCHTONE
Primary Phone Line Screen
PHONE LINE
3.6.9.2.4 Service Terminal
SERVICE TERMINAL
1=PANEL ID 0000 2=TERMINAL 1 3=TERMINAL
Service Terminal Screen #1
1=RING COUNT
3.6.9.2.4.2 Terminal 1 and Terminal
SERVICE TERMINAL # 1=PHONE NUMBER
Service Terminal # Screen
Phone Number (Service Terminal)
PHONE NUMBER
3.6.9.2.4.3 Ring Count
RING COUNT
0-25RANGE
Ring Count Screen
3.6.9.2.5 Central Station
3.6.9.2.5.2 Backup Reporting
BACKUP REPORTING 1=BACKUP ONLY 2=BOTH
3=FIRST AVAILABLE
Backup Reporting Screen
3.6.9.2.6 Trouble Call Limit (Dialer Runaway Prevention)
3.6.9.2.6.1Central Station Primary and Secondary Phone Numbers
CENTRAL STATION #
1=TEST TIME INT 24 2=ACCOUNT CODE 0000 3=24HR TST TIME
Primary/Secondary Screen #1
CENTRAL STATION 1=PHONE NUMBER
Test Time Interval
TEST TIME INTERVAL 1=24 HOURS
2=12 HOURS
3=8 HOURS
Test Time Interval Screen #1
24 Hour Test Time
24 HOUR TEST TIME
24 Hour Test Time Screen
Phone Number
Phone Number Screen
Communication Format
COMM FORMAT
1=ADEMCO EXPRESS 4P1 2=ADEMCO EXPRESS 4P2 3=3P1S C18 A23
Comm Format Screen #1
COMM FORMAT 1=3P1E C18 A23 2=3P1S C19 A14 3=3P1E C19 A14
Table 3.1 Communication Formats
Event Codes
EVENT CODES
1=PULL STATION 2=MON-USER-DEF-1
Event Code Screen
3+1, 4+1 Express and 4+1 Standard
Table 3.2 Event Codes
Table 3.2 Event Codes (continued)
4+2 Standard, 4+2 Express, 3 + 1, 4 + 1 and 4+2 Expanded Formats
Table 3.3 Event Codes
Table 3.3 Event Codes (continued)
Ademco Contact ID Format
Table 3.4 Event Codes
Table 3.4 Event Codes (continued)
Report Style
3.6.9.2.7 Manual Dial Mode
MANUAL DIAL MODE 1=PRIMARY PHONE 2=SECONDARY PHONE
MANUAL DIAL MODE 1=GO OFF HOOK 2=DIAL DIGIT(S) 3=GO ON HOOK
3.6.9.3 Printer/PC
MASTER
3.6.11 Clear Program
CLEAR PROGRAM 1=WHOLE SYSTEM 2=ALL POINTS
Clear Program Screen #1
WARNING
SYSTEM CHANGE
3.6.12 Program Check
PROGRAMCHECK 1=NACS NO INPUT 2=ZONES NO INPUT 3=ZONES NO OUTPUT
NACS NO INPUT NAC
ZONES NO INPUT
05 07 09 10 11 1M001
ZONES NO OUTPUT
05 07 09 10 11 1D001
1=READ STATUS 2=PROGRAMMING
PROGRAMMING 1=WALKTEST 2=SYSTEM
3=ZONE SETUP
3.7.1 Disable Point
POINT PROGRAM 1=DETECTOR 2=MODULE
Device Select Screen
Address Select Screen
EDIT DETECTOR 1D001
3.7.2 History
Events Screen
PROGRAMCHECK 1=NACS NO INPUT 2=ZONES NO INPUT 3=ZONE NO OUTPUT
3.7.4 Walktest
3.7.5 System
SYSTEMS 1=TIME/DATE
System Screen
TIME AND DATE 1=TIME 01:00 AM 2=DATE
12HR
Time and Date Screen
01:00 AM
1=AM
3.7.6 Zone Setup
Zone Setup Screen
SPEC
PURPOSE ZONE
1=PAS
OFF
2=PRE-SIGNAL98
Operating Instructions
AC Power
Fire Alarm
Supervisory
Trouble
Maintenance
HONEYWELL LIFE SAFETY SYSTEM ALL NORMAL 10:00A
Addressable Smoke Detectors, Monitor Modules and Control Modules
TROUBL SMOKE (PHOTO)
<ADJ> <NOUN
INVREP 10:00A 010801 1D001
Z000 10:00A 010801 1M001
ACTIVE SUPERVISORY <ADJ> <NOUN
Page
Maintenance Alert
Automatic Test Operation
Type Code Supervision
System Alarm Verification
Smoke Detector Data
Page
Page
4.20.1 Silence Inhibit Timer
4.20.2 Autosilence Timer
4.20.3 Trouble Reminder
4.20.4 Waterflow Retard Timer
4.20.5 Alarm Verification (None or One Minute)
Alarm/Shorted Condition
Open Condition
Read Status Entry
READ STATUS 1=SYSTEM POINT 2=ZONES 3=POWER
Read Status Screen #1
1=TROUBLE REMINDER 2=TIMERS
3=NACS
4.22.1 System Point
READ SYSTEM POINT
NORMAL SMOKE(PHOTO)
NORTH CLASSROOM
Z005
4.22.2 Zones
ZONES
Zones Screen #1
1=SPECIAL PURPOSE 2=ZONE TYPE 3=ZONE MESSAGE
Zones Screen #2
4.22.3 Power
BATTERY
24 V RST
Power Screen #1
CHARGER
4.22.4 Trouble Reminder
TROUBLE REMINDER
TROUBLE REM
4.22.5 Timers
PAS
4.22.6 NAC
4.22.7 Relays
4.22.8 Program Check
PROGRAM CHECK 1=NACS NO INPUT 2=ZONES NO INPUT 3=ZONES NO OUTPUT
4.22.9 History
4.22.10 Annunciators
ANNUNCIATORS
TERM ENABLED
ACS ENABLED
UDACT ENABLED
4.22.12 Central Station
CENTRAL STATION
REPORTING
ENABLED
REPORT
4.22.13 Service Terminal
SERVICE TERMINAL PANEL ID 2=TERMINAL 1 3=TERMINAL
4.22.14 Printer/PC
PRINTER PC
PRINTER PC PR4800
4.22.15 Print
PRINT
1=HISTORY
2=WALKTEST LOG 3=DETECTOR DATA
1=EXIT PRINTING
Drift Compensation
Table 4.1 Maintenance Alert Levels
DIRTY
Acceptable
Range
4.22.16 Time-Date
START
APR
WEEK
WEEK-1
SECTION 5 Central Station Communications
Table 5.1 Format Selection
Table 5.2 Format Selection Address Explanation
Page
Table 5.3 Compatible UL Listed Receivers
Remote Site Upload/Download
6.1.1 Security Features
Secret Code Verification
Time-outat Control Panel
Callback to Service Terminal
Panel Identification Number
Error Checking
Central Station Acknowledge
Central Station Data Protection
Page
Page
Power Supply Calculations
7.3.1 Overview
Table 7.2 Converting to Full Amperes
Table 7.3 System Current Draw Calculations
Table 7.4 Total Secondary Power Requirements at 24 VDC
7.4.1 NFPA Battery Requirements
7.4.2 Selecting and Locating Batteries
Page
Correlation of Input and Output Zones
Input Devices
Zones
Output Devices
Table A.1 Detector Programming Sheet Example
Table A.2 Module Programming Sheet Example
Table A.3 Blank Detector Programming Sheet - 1 of
Table A.4 Blank Module Programming Sheet - 1 of
Page
MS-9200UDLSControl Panel
Initiating Devices
Notification Appliances
NFPA 72 NATIONAL FIRE ALARM STANDARDS FOR:
NFPA 72 Central Station Service (Protected Premises Unit) or Remote Station
Page
NFPA 72 Remote Station Protective Signaling System
NFPA 72 Proprietary Protective Signaling Systems
MS-9200UDLS Addressable Fire Control Panel
MS-9200UDLSMain Board
Table D.1 MS-9200UDLSWire Specifications
E.1.1 HVAC SHUTDN
HVAC SHUTDN
E.2.1 HVAC RESTART
HVAC RESTART
E.2.2 HVAC OVRRIDE
HVAC OVRRIDE
Numerics