New ITB sensor

NOTE: This sensor cannot be tested, but you can inspect the sensor, actuator, and the flag on the ITB for damage.

1.Remove the existing ITB.

2.Inspect the new ITB sensor. Press the actuator on the sensor toward the cyan print cartridge to verify that the actuator moves.

Figure 3-24Test the new ITB sensor

3.On the new ITB, locate and inspect the new ITB flag (callout 1).

TIP: The new ITB flag is only present prior to installation. To see the flag on a previously installed ITB, insert the end of a paperclip in the hole just below the handle (callout 2) and then rotate the ITB alienation gear (callout 3).

Figure 3-25Test the new ITB sensor

23

1

ENWW

Tools for troubleshooting 271

Page 303
Image 303
HP Enterprise CC490A manual New ITB sensor, 25Test the new ITB sensor