Event log message

Description

Comments

 

 

 

54.1E.XX

Halftone calibration error

 

 

XX = 00 Bad internal data

 

 

XX = 01 Bad external data

 

 

XX = 02 Memory allocation

 

 

XX = 03 No default tables

 

 

XX = 04 Bad parameters

 

 

XX = 05 Cyan data is out of range.

 

 

XX = 06 Magenta data is out of

 

 

range.

 

 

XX = 07 Yellow data is out of range.

 

 

XX = 08 Black data is out of range.

 

 

XX = 09 Cyan data is noisy.

 

 

XX = 0A Magenta data is noisy.

 

 

XX = 0B Yellow data is noisy.

 

 

XX = 0C Black data is noisy.

 

 

 

 

54.20

Media sensor is not calibrated

 

 

 

 

54.21

Scanner beam adjustment warning

 

 

XX = 01 First scanner

 

 

XX = 02 Second scanner

 

 

 

 

54.35

Drum speed adjustment abnormality

 

 

warning

 

 

 

 

55.06.01

The DC controller NVRM has an

1. Turn the product off then on.

 

abnormal read/write.

 

2. If the error persists, replace the DC Controller. See DC controller PCA and tray on page 161.

55.06.02

The DC controller NVRM is not

 

accessible.

1.Turn the product off then on.

2.If the error persists, replace the DC Controller. See DC controller PCA and tray on page 161.

55.901C

DCC restored

DCC NVRAM was restored from the

 

 

formatter.

 

 

 

61.00.01

Color table error

This event occurs when the color table

 

 

cannot read a table from the disk and the

 

 

component reverts to the version in

 

 

RAM. The file could be corrupt, missing,

 

 

or the disk could have failed. No

 

 

messages display on the control panel.

 

 

 

67.XX.00

 

A system variable (XX) is out of range.

 

 

 

68 8X04

The permanent storage date does not

 

 

match the engine.

 

 

 

 

ENWW

Tools for troubleshooting 381

Page 413
Image 413
HP Enterprise CC490A manual DC controller Nvrm is not