Installation and Configuration

7.At each position of the server address, scroll to the correct number and press Enter to advance your cursor.

Time Server:

192.005.044.041

Figure 32: Setting the time server address

Note: Use the Escape key to backspace to a previous text box, if necessary.

When you have set the server address, the autoloader displays Enter to save.

8.Press Enter.

Time Server changed to appears on the panel display. You do not need to reboot the autoloader.

9.Press Escape or Enter to return to the Ethernet submenu.

Time

If you cannot access a time server because your server does not support SNTP or for security reasons, you can set the time manually. If you want to include time changes such as daylight savings time, you must make those changes manually as well.

Note: The DLT1 and SDLT autoloaders do not have a battery so if time is manually set, it is lost and needs to be reset whenever the autoloader is power cycled.

To set the timezone:

1. On the main menu, scroll to Configuration.