IBM SG24-5131-00 manual Switch adapter is onboard and does not need an extra slot

Models: SG24-5131-00

1 240
Download 240 pages 48.89 Kb
Page 28
Image 28

Your slot configuration must also allow for the disk I/O adapters you need to support the cluster’s shared disk (volume group) configuration. If you intend to use disk mirroring for shared volume groups, which is strongly recommended, then you will need to use slots for additional disk I/O adapters, providing I/O adapter redundancy across separate buses.

The following table tells you the number of additional adapters you can put into the different RS/6000 models. Ethernet environments can sometimes make use of the integrated ethernet port provided by some models. No such feature is available for token-ring, FDDI or ATM; you must use an I/O slot to provide token-ring adapter redundancy.

Table 4. Number of Adapter Slots in Each Model

RS/6000 Model

Number of Slots

Integrated Ethernet Port

 

 

 

 

7006

 

4 x MCA

yes

 

 

 

 

7009

C10, C20

4x PCI

no

 

 

 

7012 Mod. 3XX and GXX

4 x MCA

yes

 

 

 

7013 Mod. 5XX

7 x MCA

no

 

 

 

7013 Mod. JXX

6 x MCA, 14 x MCA

no

 

 

with expansion unit J01

 

 

 

 

7015 Mod. R10, R20, R21

8 x MCA

no

 

 

 

7015 Mod. R30, R40, R50

16 x MCA

no

 

 

 

 

7017

Mod. S7X

52 x PCI

no

 

 

 

 

7024

EXX

5 x PCI, 1 x PCI/ISA 2 x

no

 

 

ISA

 

 

 

 

 

7025

F50

6 x PCI, 2 x ISA/PCI

yes

 

 

 

 

7026

Mod. H50

6 x PCI, 2 x ISA/PCI

yes

 

 

 

7043Mod.

3 x PCI, 2 x ISA/PCI

yes

 

 

 

9076 thin node

4 x MCA

yes

 

 

 

9076 wide node

7 x MCA

no

 

 

 

9076 high node

15 x MCA

no

 

 

 

9076 thin node (silver)

2 x PCI

yes1

9076 wide node (silver)

10 x PCI

yes1

1The switch adapter is onboard and does not need an extra slot.

10 IBM Certification Study Guide AIX HACMP

Page 28
Image 28