Configuration

Figure 3-25 Port Numbers Setup Screen

6.Change the numbers by highlighting them and pressing to select the number field. Use the UP and DOWN arrows to increase or decrease the number value. The factory default Port settings are:

Remote Admin: 8200

Remote Callback:8201

Remote Watch: 8016

Remote Search:10019

Note You need to get the appropriate Port Numbers for each RASplus or a related program (Admin, Callback, Watch, and Search) from your network administrator.

Note The system restarts automatically after changing the port settings.

Note Do NOT use the same port number for two different programs. If you do, the DVR cannot be connected with the PC running RASplus.

Caution When changing the port settings, you must change the port settings on the PC running RASplus as well. Refer to the RASplus manual for details.

Using the Current LAN Settings Using DHCP

Select DHCP from the LAN Type field, highlight Save, and then press . The DHCP (Dynamic Host Configuration Protocol) network reads and configures the current IP address of the DVR.

Document 800-00918 Rev E

53

12/07

 

Page 53
Image 53