If you entered an SP IP address for the first time or changed an SP IP address, the utility reboots the storage system and the SP Boot/Fault light on the back of each SP starts blinking (Figure 51 on page 118 or Figure 52 on page 118). The reboot takes several minutes to complete. When it is completed, the SP Boot/Fault light on each SP stops blinking and remains off.

Changing the Management Network and Account Settings

STEP 1. Shut down the storage system. See Procedure 20, "Shutting the Storage System Down," on page 111.

STEP 2. Reset the storage system: At least one minute after the storage system shuts down, press the power button, hold it down for at least four seconds, and then release it. When the start-up is complete, the storage system is uninitialized. You must rerun the Navisphere Initialization Utility to reset the management network parameters and the user account settings.

STEP 3. Rerun the Navisphere Initialization Utility to set the parameters.