STEP 5. For each iSCSI data port on each SP that you will use, set the following port paramters, where X is the
Parameter
Description
SP X Port Y IP ADDRESS | IP address for the iSCSI data port. |
|
|
SP X Port Y Subnet Mask | Subnet mask associated with the LAN to which the |
| iSCSI data port will connect. |
|
|
SP X Port Y Direct Attach | Gateway address of 0.0.0.0 that you cannot change. |
| Set this parameter only if the iSCSI data port will |
| connect directly to the server and not through a LAN. |
|
|
SP X Port Y Gateway | Default gateway address for the LAN to which the |
| iSCSI data port will connect. |
|
|
STEP 6. Enter the name you want for the storage system; it cannot exceed 32 characters.
STEP 7. Using the information from the completed worksheet in the "Storage System Management Ports" section of Procedure 3, "Planning Your iSCSI Storage System Configuration," on page 15, follow the instructions on the screen to set the following management user account settings for the storage system:
Account Setting
User name
Description
Username for the management port. A valid username must start with a letter, can contain only letters and numbers, cannot exceed 32 characters, and is
Password | Password for the user connected to the management |
| port. A valid password can contain only letters and |
| numbers, cannot exceed 32 characters, and is case— |
| sensitive. For example, mousetrap2 is a valid |
| password and is a different password from |
| MOUSETRAP2. |
|
|
Confirm Password | Previously entered password for password |
| verification. |
|
|
STEP 8. Review and apply the settings.
On a Windows host,
i.Click Next to view the summary of the management user account settings for storage system.
ii.In the message box about the storage system having been initialized, click OK.
iii.If the settings are correct, click Finish.
On a Linux host,
i.Apply the values by typing a.
ii.Exit the utility by typing e.
108 | Intel Storage System SSR212PP User Guide |
| Revision 1.0 |