STEP 5. For each iSCSI data port on each SP that you will use, set the following port paramters, where X is the storage-system SP (A or B) and Y is the SP s data port number (0 or 1):

Parameter

Description

SP X Port Y IP ADDRESS

IP address for the iSCSI data port.

 

 

SP X Port Y Subnet Mask

Subnet mask associated with the LAN to which the

 

iSCSI data port will connect.

 

 

SP X Port Y Direct Attach

Gateway address of 0.0.0.0 that you cannot change.

 

Set this parameter only if the iSCSI data port will

 

connect directly to the server and not through a LAN.

 

 

SP X Port Y Gateway

Default gateway address for the LAN to which the

 

iSCSI data port will connect.

 

 

STEP 6. Enter the name you want for the storage system; it cannot exceed 32 characters.

STEP 7. Using the information from the completed worksheet in the "Storage System Management Ports" section of Procedure 3, "Planning Your iSCSI Storage System Configuration," on page 15, follow the instructions on the screen to set the following management user account settings for the storage system:

Account Setting

User name

Description

Username for the management port. A valid username must start with a letter, can contain only letters and numbers, cannot exceed 32 characters, and is case—sensitive. For example,blindmice3 is a valid username and is different from BLINDMICE3.

Password

Password for the user connected to the management

 

port. A valid password can contain only letters and

 

numbers, cannot exceed 32 characters, and is case—

 

sensitive. For example, mousetrap2 is a valid

 

password and is a different password from

 

MOUSETRAP2.

 

 

Confirm Password

Previously entered password for password

 

verification.

 

 

STEP 8. Review and apply the settings.

On a Windows host,

i.Click Next to view the summary of the management user account settings for storage system.

ii.In the message box about the storage system having been initialized, click OK.

iii.If the settings are correct, click Finish.

On a Linux host,

i.Apply the values by typing a.

ii.Exit the utility by typing e.

108

Intel Storage System SSR212PP User Guide

 

Revision 1.0

Page 122
Image 122
Intel SSR212PP manual IP address for the iSCSI data port