SSR212PP2i Connected to a Dedicated iSCSI Network (Multiple- Initiator Servers)
Figure 13 shows an SSR212PP2i with up to ten servers. Each server has two iSCSI initiators, and is connected with Ethernet switches (dedicated for iSCSI traffic) to the storage system s four iSCSI data ports. This represents a secure and highly available SSR212PP2i configuration.
Server with 2 iSCSI NICs and 1 public NIC
Corporate,
public or private
network
|
|
| iSCSI traffic |
| |
|
|
| iSCSI traffic | ||
M | anagement traf | fic | |||
| |||||
|
| ||||
|
|
|
|
|
SSR212PP2i
EMC3321
FIGURE 13. SSR212PP2i On a Dedicated LAN with Redundant Paths
Sample IP addresses
Port | IP address | Subnet mask | Gateway |
Storage Processor A iSCSI port 0 | 172.31.1.150 | 255.255.255.0 | 0.0.0.0 |
Storage Processor A iSCSI port 1 | 172.31.2.150 | 255.255.255.0 | 0.0.0.0 |
Storage Processor B iSCSI port 0 | 172.31.1.151 | 255.255.255.0 | 0.0.0.0 |
Storage Processor B iSCSI port 1 | 172.31.2.151 | 255.255.255.0 | 0.0.0.0 |
Server 1 iSCSI NIC/HBA 1 | 172.31.1.101 | 255.255.255.0 | 0.0.0.0 |
Server 1 iSCSI NIC/HBA 2 | 172.31.2.101 | 255.255.255.0 | 0.0.0.0 |
Server 2 iSCSI NIC/HBA 1 | 172.31.1.102 | 255.255.255.0 | 0.0.0.0 |
Server 2 iSCSI NIC/HBA 2 | 172.31.2.102 | 255.255.255.0 | 0.0.0.0 |
Server 3 iSCSI NIC/HBA 1 | 172.31.1.103 | 255.255.255.0 | 0.0.0.0 |
Server 3 iSCSI NIC/HBA 2 | 172.31.2.103 | 255.255.255.0 | 0.0.0.0 |
Continue for up to 10 servers . . .
Management port IP addresses should match the corporate network scheme.
Advantages
Connection to multiple servers maximizes the use of the storage system s capabilities.
Using a dedicated iSCSI LAN avoids network contention with your corporate LAN and reduces security risks
Failover capabilities in the event of a storage processor failure.
32 | Intel Storage System SSR212PP User Guide |
| Revision 1.0 |