Sample IP addresses
Port | IP address | Subnet mask | Gateway |
Storage Processor A management port | 172.31.1.200 | 255.255.255.0 | 0.0.0.0 |
Storage Processor A iSCSI port 0 | 172.31.1.150 | 255.255.255.0 | 0.0.0.0 |
Storage Processor A iSCSI port 1 | 172.31.2.150 | 255.255.255.0 | 0.0.0.0 |
Server 1 iSCSI NIC/HBA 1 | 172.31.1.101 | 255.255.255.0 | 0.0.0.0 |
Server 1 iSCSI NIC/HBA 2 | 172.31.1.102 | 255.255.255.0 | 0.0.0.0 |
Server 2 iSCSI NIC/HBA 1 | 172.31.2.101 | 255.255.255.0 | 0.0.0.0 |
Server 2 iSCSI NIC/HBA 2 | 172.31.2.102 | 255.255.255.0 | 0.0.0.0 |
Continue for up to 10 servers . . .
Management port IP addresses should match the iSCSI LAN address scheme.
Advantages
Improved security: System management requires a connection to the private network. Connection to multiple servers maximizes use of the storage system s capabilities. You can increase throughput by adding NICs to the configuration.
Connection to each SP port from both switches provides redundant data paths in case one path fails.
Disadvantages
Reduced access for remote management: To perform management tasks, you must be connected to a host on the private network.
One storage processor does not allow for failover in case of SP failure.
SSR212PP2i Connected to a Dedicated iSCSI/Management Network
Figure 16 shows a variation of the previous SSR212PP2i configuration with up to ten servers on a dedicated LAN. Each server has a single iSCSI initiator, and is connected with a single Ethernet switch to the storage system s iSCSI data and management ports.
Intel Storage System SSR212PP User Guide | 35 |