Using two storage processors improves overall storage system performance.

Connection to each SP port from both servers provides redundant data paths in case one path fails.

Disadvantages

This configuration incurs the cost of a second switch.

SSR212PPi Connected to a Dedicated iSCSI/Management Network (Single-Initiator Server)

Figure 14 shows an SSR212PPi with up to ten servers. Each server has a single iSCSI initiator, and is connected with a single Ethernet switch (used for management and iSCSI traffic) to the storage system s iSCSI data and management ports.

This configuration requires a NIC connection; iSCSI HBAs qualified on

SSR212PP-Series systems do not support management input/output.

Server with separate iSCSI NIC and public NIC

Corporate,

public or private

network

Dedicated iSCSI LAN

iSCSI traffic

SSR212PPi

EMC3318

FIGURE 14. SSR212PPi On a Dedicated LAN with Limited Access to Management Ports

Sample IP addresses

Port

IP address

Subnet mask

Gateway

Storage Processor A management port

172.31.1.200

255.255.255.0

0.0.0.0

Storage Processor A iSCSI port 0

172.31.1.150

255.255.255.0

0.0.0.0

Storage Processor A iSCSI port 1

172.31.1.151

255.255.255.0

0.0.0.0

Server 1 iSCSI NIC/HBA 1

172.31.1.101

255.255.255.0

0.0.0.0

Server 2 iSCSI NIC/HBA 1

172.31.1.102

255.255.255.0

0.0.0.0

Server 3 iSCSI NIC/HBA 1

172.31.1.103

255.255.255.0

0.0.0.0

Continue for up to 10 servers . . .

Intel Storage System SSR212PP User Guide