Applying iSCSI Data Port

Addresses to the SP

Assembly

31

Perform the following procedure after replacing an iSCSI storage processor assembly. Replacing a Fibre Channel assembly does not require these steps.

STEP 1. Start Navisphere Express on a management server. See Procedure 29, "Running Navisphere Express," on page 163.

STEP 2. Select Services from the System options, and then Reboot.

STEP 3. Select Reboot both SPs.

The storage system takes several minutes to reboot. You can monitor the LEDs on the back of the system, or simply wait until the system allows you to restart Navisphere Express from the System Reboot page.

STEP 4. Repeat Steps 1—3.

STEP 5. Restart Navisphere Express (STEP 1).

STEP 6. Select iSCSI from the Manage options, then click Apply.

STEP 7. From the Manage iSCSI page, select Test.