SSR212PPi Directly Connected to One Server
Figure 5 shows one server, with two iSCSI initiators, directly cabled to an SSR212PPi s iSCSI data ports.
Server with separate iSCSI NIC and public NIC
Corporate, |
| DAS iSCSI | |
public or private | iSCSI traffic | ||
and public LAN | |||
network |
| ||
| |||
|
|
Management traffic
SSR212PPi |
EMC3311
FIGURE 5. SSR212PPi (Single SP) Directly Connected to One Server
Sample IP Addresses
Port | IP address | Subnet mask | Gateway |
Storage Processor A iSCSI port 0 | 172.31.1.150 | 255.255.255.0 | 0.0.0.0 |
Storage Processor A iSCSI port 1 | 172.31.2.150 | 255.255.255.0 | 0.0.0.0 |
iSCSI NIC/HBA 1 | 172.31.1.101 | 255.255.255.0 | 0.0.0.0 |
iSCSI NIC/HBA 2 | 172.31.2.101 | 255.255.255.0 | 0.0.0.0 |
|
|
|
|
Management port IP addresses should match the corporate network scheme.
Advantages
You can easily migrate this
The dedicated iSCSI path ensures maximum throughput from the host to the storage system.
The dedicated path provides inherent security.
Disadvantages
Since only one server can connect to the storage system, this configuration does not take full advantage of the SSR212PPi s connectivity capabilities.
While this configuration provides port failover and load balancing, it does not allow SP failover.
24 | Intel Storage System SSR212PP User Guide |
Revision 1.0